Publication:
Potansiyometrik Esaslı Bazı İmmünosensörlerin Hazırlanması ve Uygulamaları

dc.contributor.advisorTınkılıç, Nihat
dc.contributor.authorEren, Emel
dc.date.accessioned2020-07-21T21:39:46Z
dc.date.available2020-07-21T21:39:46Z
dc.date.issued2008
dc.departmentOMÜ, Fen Bilimleri Enstitüsü, Kimya Anabilim Dalıen_US
dc.departmentFen Bilimleri Enstitüsü / Kimya Bölümü / Kimya Ana Bilim Dalı
dc.descriptionTez (yüksek lisans) -- Ondokuz Mayıs Üniversitesi, 2008en_US
dc.descriptionLibra Kayıt No: 12446en_US
dc.description.abstractBu çalışmada, brusella antijeni ve anti-rabbit IgG antikoru kullanılarak PVC ve PVC-NH2 de temel teşkil eden brusella ve anti-rabit IgG potansiyometrik immünosensörler hazırlandı. Hazırlanan sensörlerin potansiyometrik performansları bilgisayar kontrollü potansiyometrik sistem kullanılarak test edildi. PVC temelli brusella immünosensör 3,125-50 ng/mL konsantrasyon aralığında anti-brusellaya doğrusal davranış sergilerken (R2 = 0,993), PVC-NH2 temelli brusella immünosensör 6,25-100 ng/mL konsantrasyon aralığında anti-brusellaya doğrusal davranış sergilemekteydi (R2 = 0,997). PVC ve PVC-NH2 anti rabbit IgG immünosensörlerin her ikisi de 25-200 ng/mL konsantrasyon aralığında rabit IgG ye karşı doğrusal davranış sergilemekteydi (R2 = 0,995 her iki immünosensör için). Bütün immünosensörlerin cevap zamanı oldukça uzundu. Genel olarak konsantrasyon arttıkça cevap zamanında artış gözlemlendi. Geliştirilen immünosensörlerle bir örnek çözeltiden 3-5 kez tekrarlanabilir potansiyometrik sinyal elde edildi.
dc.description.abstractIn the present study, Brucella and anti-rabit IgG potentiometric immunosensors based on PVC and PVC-NH2 were prepared by using brucella antigen and anti-rabit IgG antibody. Potentiometric performances of the immunosensors prepared were tested using a computer controlled potentiometric system. Brucella immunosensor based on PVC-NH2 exhibited a linear response between 6,25-100 ng/mL anti-brucella concentrations (R2 = 0,993) while brucella immunosensor based on PVC exhibited a linear response between 3,125-50 ng/mL anti-brucella concentrations (R2 = 0,997). Anti-rabit IgG immunosensors based on PVC and PVC-NH2 both produced a linear response with R2 = 0,995 between 25-200 ng/mL rabbit IgG concentartions. The responses of the immunosensors used were found highly time consuming. In general, the response time of the immunosensors increased with the increase of sample concentration. So far, for a sample solution, the developed immunosensors exhibited reproducible signals up to 3-5 measurementsen_US
dc.formatIX, 70 y. : şekil, tablo ; 30 sm.en_US
dc.identifier.endpage82
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=wBmNpkQC9Nhi90NLW7E7-VA0H0naCfVgAnpR2cqSGM02V8g7Yuak7j7DkQO3UU2V
dc.identifier.urihttp://libra.omu.edu.tr/tezler/12446.pdf
dc.identifier.urihttps://hdl.handle.net/20.500.12712/27409
dc.identifier.yoktezid213410
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Fen Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKimya
dc.subjectİmmünosensör
dc.subjectChemistryen_US
dc.subjectImmunosensoren_US
dc.subject.otherTEZ YÜK LİS E67p 2008en_US
dc.titlePotansiyometrik Esaslı Bazı İmmünosensörlerin Hazırlanması ve Uygulamaları
dc.titlePreparation of Potentiometric Immunosensors and Their Applicationsen_US
dc.typeMaster Thesisen_US
dspace.entity.typePublication

Files