Publication:
Bazı Yeni Ditiyokarbamat Reaktiflerinin Sentezi ve Eser Metallerin Faas ile Tayininde Kullanılması

dc.contributor.advisorBatı, Bekir
dc.contributor.authorCesur, Hasan
dc.date.accessioned2020-07-21T21:36:30Z
dc.date.available2020-07-21T21:36:30Z
dc.date.issued2000
dc.departmentOMÜ, Fen Bilimleri Enstitüsü, Kimya Anabilim Dalıen_US
dc.departmentFen Bilimleri Enstitüsü / Kimya Ana Bilim Dalı
dc.descriptionTez (doktora) -- Ondokuz Mayıs Üniversitei, 2000en_US
dc.descriptionLibra Kayıt No: 35544en_US
dc.description.abstractBAZI yeni ditiyokarbamat reaktiflerinin sentezi ve eser METALLERİN FAAS İLE TAYİNİNDE KULLANILMASI ÖZET Bu çalışmada, yeni reaktif olarak, potasyum 4-benzilpiperidinditiyokarbamat (K4-BPDC), potasyum 1-benzilpiperazinditiyokarbamat (Kl-BPzDC), potasyum l-(4-nitrofenil)piperazinditiyokarbamat [Kl-(NF)PzDC], ve potasyum l-(4-florfenil)- piperazinditiyokarbamat [Kl-(FF)PzDC] bileşikleri sentezlendi ve Mn(II), Fe(III), Ni(II), Co(II), Cu(II), Zn(II), Cd(II) ve Pb(II) un, zenginleştirilmesi ve ayrılması işlemlerinde kullanılabilirliği araştırıldı. Aynı şartlarda, potasyum 4-metil- piperidinditiyokarbamat (K4-MPDC), potasyum 1-metilpiperazinditiyokarbamat (Kl-MPzDC) ve sodyum dietilditiyo-karbamat (NaDDC) reaktifleri ile de çalışılarak karşılaştırma yapıldı. Ditiyokarbamat grubundaki hidrofobik grubun büyümesi ile ekstraksiyon veriminde ve sulu çözeltilerinin kararlılığında artış gözlendi. Bu sonuçlardan hareket ederek potasyum 1-benzilpiperazinditiyokarbamat kullanılarak, başta çevresel örnekler olmak üzere diğer pek çok alanda tayini önemli olan ve alevli atomik absorpsiyon spektrometrisi (FAAS) ile direkt olarak tayin edilemeyen kadmiyumun önderiştirilmesi ve FAAS ile tayin edilmesi için yeni bir yöntem geliştirildi. Bu yöntem, Kl-BPzDC reaktifı ile sulu fazda oluşturulan kadmiyum kompleksinin mikrokristal naftalin ile katı faza alınması ve potasyum siyanür çözeltisi ile geri ekstrakte edilerek sulu fazın FAAS ile ölçülmesine dayanmaktadır. Buna göre son potasyum siyanür çözeltisindeki kadmiyum derişimi 0.5-3 mgL'1 arasında olduğunda doğrusallık (r2 = 0.9992 ) tespit edildi, gözlenebilme sının 0.034 mgL'1 ve tayin sının 0.1 14 mgL'1 olarak hesaplandı. Metodun doğruluğu kadmiyum içeren bir standart alaşım (MBH) kullanılarak test edildi. Geliştirilen yöntem, içme ve deniz suyu örneklerine uygulanarak kadmiyum tayini yapıldı. Anahtar Kelimeler : Ditiyokarbamat, katı-faz ekstraksiyonu, FAAS, kadmiyum tayini
dc.description.abstractSYNTHESIS OF SAME NOVEL DITHIOCARBAMATE REAGENTS AND THEIR USING AT TRACE METAL ANALYSIS BY FAAS ABSTRACT In this study, potassium 4-benzylpiperidinedithiocarbamate (K4-BPDC), potassium 1-benzylpiperazinedinedithiocarbamate (Kl-BPzDC), potassium l-(4-nit- rophenyl)piperazinedithiocarbamate [Kl-(NF)PzDC] and potassium l-(4-fluoro- phenyl)piperazinedithiocarbamate [Kl-(FF)PzDC] compounds were synthesised as new reagents. The usability of these compouns in the pre-concentration and separation of Mn(II), Fe(III), Ni(II), Co(II), Cu(II), Zn(II), Cd(II) and Pb(II) were investigated. Potassium 4-methylpiperidinedithiocarbamate (K4-MPDC), potassium 1-methylpipe- razinedithiocar-bamate (Kl-MPzDC) and sodium diethyldithiocarbamate (NaDDC) were studied at same conditions and their extraction properties were also compared. It was observed that the extraction efficiency and their stability in aqueous phase increased when substituted groups size, which bonded N-atom increases. Thus, using The 1-benzylpiperazinedinedithiocarbamate reagent a method was developed for the simultaneous pre-concentration and determination of cadmium by FAAS, which is very important for environmental and other sources of samples that can not be determined by FAAS directly. The present method based on the adsorbtion of cadmium 1-benzylpipe- razinedinedithiocarbamate complex formed in aqueous phase on solid microcrystalline naphthalene phase and elution of cadmium with potassium cyanide solution in to aqueous phase and measuring by FAAS. Experimental results showed that cadmium concentration in final potassium cyanide solution shows a linear relationship (r =0.9992) between 0.5-3 mgL concentration level and thus, obeys the Beer's law. The limit of detection and limit of quantification were calculated as 0.034 mgL'1 and 0.114 mgL'1 respectively. The accuracy of the method was tested with standard reference material ( MBH ) and the determination of cadmium was carried out in tap water and sea water samples. Key Words: Dithiocarbamate, solid-phase extraction, FAAS, determination of cadmiumen_US
dc.formatX, 100 y. : şekil ; 30 sm.en_US
dc.identifier.endpage100
dc.identifier.urihttp://libra.omu.edu.tr/tezler/35544.pdf
dc.identifier.yoktezid96886
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Fen Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKimya
dc.subjectAtomik Soğurma Spektrometri
dc.subjectDitiyokarbamat
dc.subjectEser Elementler
dc.subjectSentez
dc.subjectChemistryen_US
dc.subjectAtomic Absorption Spectrometryen_US
dc.subjectDithiocarbamateen_US
dc.subjectTrace Elementsen_US
dc.subjectSynthesisen_US
dc.subject.otherTEZ DOK C422b 2000en_US
dc.titleBazı Yeni Ditiyokarbamat Reaktiflerinin Sentezi ve Eser Metallerin Faas ile Tayininde Kullanılması
dc.titleSynthesis of Some Novel Dithiocarbamate Reagents and Their Use in Trace Metal Analysis by FAASen_US
dc.typeDoctoral Thesisen_US
dspace.entity.typePublication

Files