Publication:
Light Transmittance and Surface Roughness of a Feldspathic Ceramic CAD-CAM Material as a Function of Different Surface Treatments

dc.authorscopusid14046455100
dc.authorscopusid36552323600
dc.authorscopusid57191167822
dc.authorscopusid57190748779
dc.authorscopusid21736455800
dc.authorscopusid15063768900
dc.contributor.authorUral, Ç.
dc.contributor.authorDuran, I.
dc.contributor.authorEvmek, B.
dc.contributor.authorKavut, I.
dc.contributor.authorCengiz, S.
dc.contributor.authorYüzbaşıoğlu, E.
dc.date.accessioned2020-06-21T13:32:37Z
dc.date.available2020-06-21T13:32:37Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Ural] Çaĝri, Department of Prosthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Duran] Ibrahim, Department of Prosthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Evmek] Betül, Department of Prosthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Kavut] İdris, Department of Prosthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Cengiz] Seda, Department of Prosthodontics, Zonguldak Bulent Ecevit University, Zonguldak, Zonguldak, Turkey; [Yüzbaşıoğlu] Emir, Department of Prosthodontics, İstanbul Medipol Üniversitesi, Istanbul, Beykoz, Turkey, Department of Medical Biology and Regenerative and Restorative Medicine Research Center (REMER), İstanbul Medipol Üniversitesi, Istanbul, Beykoz, Turkeyen_US
dc.description.abstractBackground: The aim of the present study was to determine the effect of different surface treatments on light transmission of aesthetic feldspathic ceramics used in CAD-CAM chairside restorations. Methods: Forty eight feldspatic ceramic test specimens were prepared from prefabricated CAD-CAM blocks by using a slow speed diamond saw. Test specimens were prepared and divided into 4 groups (n = 12). In the control group, no surface treatments were applied on the feldspathic ceramic surfaces. In the hydrofluoric acid group, the bonding surfaces of feldspathic ceramics were etched with 9.5 % hydrofluoric acid. In the sandblasting group the feldspathic ceramic surfaces were air-abraded with 30-μm alumium oxide (Al<inf>2</inf>O<inf>3</inf>) particles and Er:YAG laser was used to irradiate the ceramic surfaces. The incident light power given by the LED device and the transmitted light power through each ceramic sample was registered using a digital LED radiometer device. Each polymerization light had a light guide with 8-mm-diameter tips. Light transmission of feldspathic ceramic samples was determined by placing it on the radiometer and irradiating the specimen for 10 s at the highest setting for each light polymerization. All specimens were coated with gold using a sputter coater and examined under a field emission scanning electron microscope. Surface roughness measurement each group were evaluated with 3D optical surface and tactile profilometers. Results: One-way ANOVA test results revealed that both surface conditioning method significantly affect the light transmittance (F:412.437; p < 0.001) and the surface roughness values (F:16.386; p < 0.001). Al<inf>2</inf>O<inf>3</inf> and Er-YAG laser application reduced the light transmission significantly (p < 0.05). Conclusions: The laser and Al<inf>2</inf>O<inf>3</inf> applications reduced the light transmission of 1.5 mm thickness feldspathic ceramic material below the value of 400 mW/cm2 which is critical limit for safe polymerization. © 2016 The Author(s).en_US
dc.identifier.doi10.1186/s12903-016-0245-5
dc.identifier.issn1472-6831
dc.identifier.issue1en_US
dc.identifier.pmid27418002
dc.identifier.scopus2-s2.0-84987748050
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1186/s12903-016-0245-5
dc.identifier.volume17en_US
dc.identifier.wosWOS:000379721400001
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherBioMed Central Ltd. info@biomedcentral.comen_US
dc.relation.ispartofBMC Oral Healthen_US
dc.relation.journalBmc Oral Healthen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCAD-CAM Blocksen_US
dc.subjectFeldspathic Ceramicen_US
dc.subjectLaser Treatmenten_US
dc.subjectLight-Transmissionen_US
dc.titleLight Transmittance and Surface Roughness of a Feldspathic Ceramic CAD-CAM Material as a Function of Different Surface Treatmentsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files