Publication:
Bütünüyle Katı-hal Kontakt Amonyum-seçici Pvc-membran Kondüktometrik Elektrotlar ve Performans Karakteristikleri

dc.contributor.advisorIşıldak, İbrahim
dc.contributor.authorTurak, Celal
dc.date.accessioned2020-07-21T21:39:31Z
dc.date.available2020-07-21T21:39:31Z
dc.date.issued2003
dc.departmentOMÜ, Fen Bilimleri Enstitüsü, Kimya Anabilim Dalıen_US
dc.departmentFen Bilimleri Enstitüsü / Kimya Ana Bilim Dalı
dc.descriptionTez (yüksek lisans) -- Ondokuz Mayıs Üniversitesi, 2003en_US
dc.descriptionLibra Kayıt No: 39392en_US
dc.description.abstract11 BÜTÜNÜYLE KATI-HAL KONTAKT AMONYUM-SEÇİCİ PVC-MEMBRAN KONDÜKTOMETRİK ELEKTROTLAR VE PERFORMANS KARAKTERİSTİKLERİ ÖZET Nonaktin, dibenzo-18-crown-6 ve disüdo-18~crown-6 gibi crown-eter bileşikleri (nötral iyonoforlar olarak) kullanılarak tümüyle katı-hal kontakt PVC-membran NH/- seçici elektrotlar hazırlandı. Elektrotların kondüktometrik ve potansiyometrik performansları bilgisayarlı bir ölçüm sisteminde araştırıldı. Hazırlanan elektrotların tamamına yakını ana iyon çözeltisine karşı Nernst davranışı gösterirken (>60 mV/her 10 kat değişim), cevap zamanları kısa (<15 s) ve kullanım ömürleri uzundu (en az 1-2 ay). or -i Tüm elektrotlar 10' -10' mol.L' konsantrasyon aralığında ana iyon çözeltisine karşı doğrusal davranış sergilemekteydi. Elektrotların ana iyon yanında girişim yapan iyonlara karşı seçicilik katsayıları ayrı çözelti metodu ile hesaplandı. A ve D ile ifade edilen membran elektrotlar NHU+ iyonuna karşı Na+ ve K+ iyonları yanında oldukça yüksek kondüktometrik ve potansiyometrik seçicilik sergilediği, B ve C membran elektrotların ise çözeltide NH41' iyonuna karşı düşük düzeyde seçicilik sergilediği sonucuna varıldı. Genel olarak, bütünüyle katı-hal kontakt NHU+ seçici membran elektrotların kondüktometrik sistemde NH4+ iyonuna karşı seçiciliği potansiyometrik sistemle kıyaslandığında azaldı. Ayrıca elektrotların düşük hücre hacimli akış hücreleri hazırlanarak hareketli ortamlarda da ölçümler alındı. D membran bileşimi ile hazırlanan elektrot kullanılarak, amonyumun toprak numunelerinde tayini kondüktometrik ve potansyometrik-akış enjeksiyon sistemlerinde başarıyla gerçekleştirildi. Anahtar Kelimeler : PVC-membran Elektrotlar, Bütünüyle Katı-Hal, Seçici kondüktometri, Amonyum, Toprak Analizi.
dc.description.abstractIll ALL SOLID-STATE CONTACT AMMONIUM-SELECTIVE PVC- MEMBRANE CONDUCTOMETRIC ELECTRODES AND THEIR PERFORMANCE CHARACTERISTICS ABSTRACT All solid-state contact PVC-membrane NH4+-selective electrodes were prepared by using crown-ether compounds Nonactin, dibenzo-18-crown-6 and dicyclo-18-crown-6 as neutral ionofores. The conductometric and potentiometric performances of electrodes were examined with a computerized measuring system. All electrodes almost exhibited Nernstian behaviour (>60 mV/per decade), short response times (<15 s) and long life times (at least 1-2 months) with a linear response between 10'2-10'5 mol.L'1 solutions of primary ion. Selectivity cofficients of the electrodes againt potential interferent ions were calculated by separate solution method. Membrane electrodes A and D exhibited a high degree of conductometric and potentiometric selectivity toward NH/ against Na+ and K+ ions. Although membrane electrodes B and C resulted a limeted selectivity toward NH4+ ion in solution. All solid-state NH/ selective membrane electrodes applied in the potentiometric form of the measurement behaved more selective toward NH4+ than applied in the conductometric form of the measurment selectivity of all solid-state NHU+ selective membrane electrodes toward NH/ ion was diminished by applying conductometry. Flow-through cells for the electrodes were designed and used in flowing conditions. Electrodes prepared with D membrane, ammonium ion was determined successfully in soil samples by the use of conductometric and potentiometric-flow injection system. Keywords : PVC-Membrane Electrodes, All Solid-State, Selective Conductometry, Ammonium, Soil Analysis.en_US
dc.formatXI, 70 y. : şekil, tablo. ; 30 sm.en_US
dc.identifier.endpage83
dc.identifier.urihttp://libra.omu.edu.tr/tezler/39392.pdf
dc.identifier.yoktezid135980
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Fen Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKimya
dc.subjectAmonyum Bileşikleri
dc.subjectElektrotlar
dc.subjectKondüktometri
dc.subjectChemistryen_US
dc.subjectToprak Analizi
dc.subjectAmmonium Compoundsen_US
dc.subjectElectrodesen_US
dc.subjectConductometryen_US
dc.subjectSoil Analysisen_US
dc.subject.otherTEZ YÜK LİS T929b 2003en_US
dc.titleBütünüyle Katı-hal Kontakt Amonyum-seçici Pvc-membran Kondüktometrik Elektrotlar ve Performans Karakteristikleri
dc.titleAll Solid-State Contact Ammonium-Selective PVC-Membrane Conductometric Electrodes and Their Performance Characteristicsen_US
dc.typeMaster Thesisen_US
dspace.entity.typePublication