Publication: Hareketli Ortamlarda Kullanılabilen Düşük Hücre Hacimli Katı-hal Kompozit Elektrotların Hazırlanması
| dc.contributor.advisor | Işıldak, İbrahim | |
| dc.contributor.author | Ünal, Hikmet | |
| dc.date.accessioned | 2020-07-21T21:39:38Z | |
| dc.date.available | 2020-07-21T21:39:38Z | |
| dc.date.issued | 1998 | |
| dc.department | OMÜ, Fen Bilimleri Enstitüsü, Kimya Anabilim Dalı | en_US |
| dc.department | Fen Bilimleri Enstitüsü / Analitik Kimya Ana Bilim Dalı | |
| dc.description | Tez (yüksek lisans) –Ondokuz Mayıs Üniversitesi, 1998 | en_US |
| dc.description | Libra Kayıt No: 31055 | en_US |
| dc.description.abstract | Ill HAREKETLİ ORTAMLARDA KULLANILABİLEN DÜŞÜK HÜCRE HACİMLİ KATI-HAL KOMPOZİT ELEKTROTLARIN HAZIRLANMASI ÖZET İyon kromatografik analizlerde yeni dedektör sistemlerine duyulan ihtiyaç, süregelen ve problemdir. Grafit, epoksi ve bir sertleştiricinin temel teşkil ettiği katı-hal kompozit elektrotlar, iyon kromatografide dedektör olarak kullanılmak amacıyla hareketli ortamlarda test edilmiştir. Hareketli faz olarak su ve çeşitli tuz çözeltileri kullanılmış, yaklaşık 5 fil hücre hacmine sahip anyon ve katyon duyarlı kompozit elektrotların çok düşük konsantrasyonlarda çok sayıda anyon ve katyona karşı cevap sergiledikleri gözlenmiştir. Elektrotlar 5 ay süresince yapılan testlerde kısa cevap zamanı ve yaklaşık Nernst kanununa uygun davranış göstermişlerdir. Hazırlanan kompozit elektrot dedektörler ekonomik ve basit dizaynı ile hareketli ortamlarda kolayca uygulanabilmektedir. Anahtar Kelimeler: Katı-Hal Elektrot, Kompozit Elektrot, İyon-Seçici Elektrot, Hareketli Ortam. | |
| dc.description.abstract | IV ABSTRACT The need to develop new detection methods in ion chromatographic systems is a continuing problem. Solid-state composite electrodes based on graphit-epoxy and hardener incorporating active material were tested as dedector for ion chromatography in flowing conditions. Deionized water and different salt solutions were used as mobile phase in flow-through measurements. Composite anion and cation-selective electrode which has almost 5 ul flow-through cell showed response to many anions and cations at low concentrations. In 5 months time, the preprared electrodes exhibited short response time and nearly Nernst behaviour. Composite anion and cation-selective electrodes prepared as detectors are cheap, easy to construct and simple to use in flowing conditions employed in ion chromatographic purposes. Key Words: Solid-state electrode, Composite electrode, Ion-selective electrode, Flowing condition. | en_US |
| dc.format | IX, 39 y. : şekil ; 30 sm. | en_US |
| dc.identifier.endpage | 49 | |
| dc.identifier.uri | http://libra.omu.edu.tr/tezler/31055.pdf | |
| dc.identifier.yoktezid | 78570 | |
| dc.language.iso | tr | en_US |
| dc.language.iso | tr | |
| dc.publisher | Ondokuz Mayıs Üniversitesi, Fen Bilimleri Enstitüsü | en_US |
| dc.relation.publicationcategory | Tez | en_US] |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Kimya | |
| dc.subject | Dedektörler | |
| dc.subject | Katıhal Elektrot | |
| dc.subject | İyon Kromatografisi | |
| dc.subject | Chemistry | en_US |
| dc.subject | Detectors | en_US |
| dc.subject | Solid State Electrode | en_US |
| dc.subject | Ion Chromatography | en_US |
| dc.subject.other | TEZ YÜK LİS Ü54h | en_US |
| dc.title | Hareketli Ortamlarda Kullanılabilen Düşük Hücre Hacimli Katı-hal Kompozit Elektrotların Hazırlanması | |
| dc.title | The Preparation of Potentiometric Composite Electrodes with Low Flow-Through Cell Which Can Be Used in Flowing Conditions | en_US |
| dc.type | Master Thesis | en_US |
| dspace.entity.type | Publication |
