Publication: Trioktilamin ve Tridodesilaminde Temel Teşkil Eden Bütünüyle Katı-Hal PVC Membran Potansiyometrik pH Sensörler
| dc.contributor.advisor | Asan, Adem | |
| dc.contributor.author | Genç, Selda | |
| dc.date.accessioned | 2020-07-21T21:39:43Z | |
| dc.date.available | 2020-07-21T21:39:43Z | |
| dc.date.issued | 2006 | |
| dc.department | OMÜ, Fen Bilimleri Enstitüsü, Kimya Anabilim Dalı | en_US |
| dc.department | Fen Bilimleri Enstitüsü / Kimya Ana Bilim Dalı | |
| dc.description | Tez (yüksek lisans) -- Ondokuz Mayıs Üniversitesi, 2006 | en_US |
| dc.description | Libra Kayıt No: 16958 | en_US |
| dc.description.abstract | Bu çalışmada bilinen bir ticari hidrojen iyonofor olan TOA (trioktilamin) veTDDA (tridodesilamin) aktif maddeleri kullanılarak bütünüyle katı-hal PVC ve PVC-NH2 membran kompozit pH sensörler hazırlandı. Sensörlerin potansiyometrikperformansları bilgisayar kontrollü bir ölçüm sisteminde araştırıldı. Hazırlanan bütünpH sensörler, geniş doğrusal pH aralığına, yüksek seçiciliğe, uzun kullanım ömrüne (8-12 hafta) sahipti. PVC-NH2 kullanılarak hazırlanan bütünüyle katı-hal pH sensörlerinPVC kullanılarak hazırlanan bütünüyle katı-hal pH sensörlerden daha kısa cevapzamanına (yaklaşık 5 s) sahip olduğu gözlendi. Özellikle TOA ve PVC-NH2 ilehazırlanan pH sensörün, kısa cevap zamanının yanı sıra diğerine göre daha geniş birdoğrusal pH aralığına (2-13) sahip olduğu gözlendi. Hem TOA hem de TDDA ilehazırlanan bütünüyle katı-hal PVC ve PVC-NH2 membran kompozit pH sensörler içinseçicilik katsayıları ?karışık çözelti metodu? kullanılarak, Na+, K+, Li+, NH + ve Ca2+4iyonları yanında H3O+ iyonu için hesaplandı. Ayrıca TOA ve PVC-NH2 kullanılarakhazırlanan bütünüyle katı-hal kompozit pH sensör, akış-enjeksiyon analiz (FIA)sisteminde dedektör olarak kullanılarak farklı pH değerine sahip tampon çözeltiler içindeğişimler incelendi.Anahtar Kelimeler: pH sensör; Bütünüyle katı-hal kompozit elektrot; PVC veya PVC-NH2 membran elektrot; Trioctylamine; Tridodecylamine | |
| dc.description.abstract | In this work, all solid-state contact PVC and PVC-NH2 membrane pH selectiveelectrodes were prepared by using commonly known trioctylamine (TOA) andtridodecylamine as hydrogen ionofores. The potentiometric performance characteristicswere examined with a computerized measuring system. All pH electrodes almostexhibited long life times (8-12 months), long lineer pH range, high selectivity. All solid-state contact PVC-NH2 pH sensors were obtained short response time (almost 5 s).Selective coefficientsof the all solid-state contact PVC and PVC-NH2 membrane pHsensors for against interfering ions (Na+, K+, Li+, NH4+ and Ca2+) were calculated by?mixed solution method? for the H3O+ ion. In the other hand, solid-state contact TOAPVC-NH2 pH electrode was used a dedector different but for solutions in the flow-injection analysis (FIA) system.Anahtar Kelimeler: pH sensor; All solid-state composite electrode; PVC or PVC-NH2membrane electrode; Trioctylamine; Tridodecylamine | en_US |
| dc.format | XVIII, 102 y. : şekil, tablo ; 30 sm. | en_US |
| dc.identifier.endpage | 122 | |
| dc.identifier.uri | https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=-L8ilcwn9ZRRc_YMKxXW1sgPq10BdgTCjD25AttyZ2H3W4bbE7NfhbBlRTV0N7Og | |
| dc.identifier.uri | http://libra.omu.edu.tr/tezler/16958.pdf | |
| dc.identifier.yoktezid | 185789 | |
| dc.language.iso | tr | en_US |
| dc.language.iso | tr | |
| dc.publisher | Ondokuz Mayıs Üniversitesi, Fen Bilimleri Enstitüsü | en_US |
| dc.relation.publicationcategory | Tez | en_US] |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Chemistry | en_US |
| dc.subject | Kimya | |
| dc.subject.other | TEZ YÜK LİS G324t 2006 | en_US |
| dc.title | Trioktilamin ve Tridodesilaminde Temel Teşkil Eden Bütünüyle Katı-Hal PVC Membran Potansiyometrik pH Sensörler | |
| dc.title | All-Solid-State Contact PVC Membrane Potentiometric pH Sensors Based on Trioctylamine and Tridodecylamine | en_US |
| dc.type | Master Thesis | en_US |
| dspace.entity.type | Publication |
