Publication:
Characterization of Indoor and Outdoor Electric Field Strength Levels at Hospitals

dc.authorscopusid16230640200
dc.authorscopusid57205618850
dc.contributor.authorKurnaz, C.
dc.contributor.authorAygun, T.
dc.date.accessioned2020-06-21T13:12:02Z
dc.date.available2020-06-21T13:12:02Z
dc.date.issued2018
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Kurnaz] Çetin, Department of Electrical and Electronic Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Aygun] Tulay, Department of Electrical and Electronic Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description"Telekom Srbija" ad.; Ericsson; et al.; ETF - School of Electrical Engineering, University of Belgrade; Ministry of Trade, Turism and Telecommunications; Vlatacom d.o.oen_US
dc.description.abstractIn this study, electrical field strength (E) level measurements were conducted in indoor and outdoor at seven hospitals in the city center of Samsun/Turkey. E measurements were made with Narda SRM-3006 electromagnetic field meter, which can measure the frequency band between 30 MHz and 3 GHz selectively. Measurements results show that the highest E value within the hospital is 0.818 V/m, while this value is 2.627 V/m for out of hospital. The E exposed outdoor of the hospital is 2.93 times higher than indoor of the hospital for measurement locations. The main sources of total E in the environments are base stations, and their contributions are 92.5% and 98.6% for indoor and outdoor of the hospital respectively. The most contribution of 53.4% total E is base stations using 2100 MHz frequency. © 2018 IEEE.en_US
dc.identifier.doi10.1109/TELFOR.2018.8611906
dc.identifier.endpage167en_US
dc.identifier.isbn9781538671702
dc.identifier.scopus2-s2.0-85062076581
dc.identifier.startpage164en_US
dc.identifier.urihttps://doi.org/10.1109/TELFOR.2018.8611906
dc.identifier.wosWOS:000459714200041
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.relation.ispartof-- 26th Telecommunications Forum, TELFOR 2018 -- 2018-11-20 Through 2018-11-21 -- Belgrade -- 144370en_US
dc.relation.journal2018 26Th Telecommunications Forum (Telfor)en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBand Selective E Measurementsen_US
dc.subjectBase Stationen_US
dc.subjectElectric Field Strength (E)en_US
dc.subjectElectromagnetic Fielden_US
dc.subjectSRM-3006en_US
dc.titleCharacterization of Indoor and Outdoor Electric Field Strength Levels at Hospitalsen_US
dc.typeConference Objecten_US
dspace.entity.typePublication

Files