Publication: Characterization of Indoor and Outdoor Electric Field Strength Levels at Hospitals
| dc.authorscopusid | 16230640200 | |
| dc.authorscopusid | 57205618850 | |
| dc.contributor.author | Kurnaz, C. | |
| dc.contributor.author | Aygun, T. | |
| dc.date.accessioned | 2020-06-21T13:12:02Z | |
| dc.date.available | 2020-06-21T13:12:02Z | |
| dc.date.issued | 2018 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Kurnaz] Çetin, Department of Electrical and Electronic Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Aygun] Tulay, Department of Electrical and Electronic Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description | "Telekom Srbija" ad.; Ericsson; et al.; ETF - School of Electrical Engineering, University of Belgrade; Ministry of Trade, Turism and Telecommunications; Vlatacom d.o.o | en_US |
| dc.description.abstract | In this study, electrical field strength (E) level measurements were conducted in indoor and outdoor at seven hospitals in the city center of Samsun/Turkey. E measurements were made with Narda SRM-3006 electromagnetic field meter, which can measure the frequency band between 30 MHz and 3 GHz selectively. Measurements results show that the highest E value within the hospital is 0.818 V/m, while this value is 2.627 V/m for out of hospital. The E exposed outdoor of the hospital is 2.93 times higher than indoor of the hospital for measurement locations. The main sources of total E in the environments are base stations, and their contributions are 92.5% and 98.6% for indoor and outdoor of the hospital respectively. The most contribution of 53.4% total E is base stations using 2100 MHz frequency. © 2018 IEEE. | en_US |
| dc.identifier.doi | 10.1109/TELFOR.2018.8611906 | |
| dc.identifier.endpage | 167 | en_US |
| dc.identifier.isbn | 9781538671702 | |
| dc.identifier.scopus | 2-s2.0-85062076581 | |
| dc.identifier.startpage | 164 | en_US |
| dc.identifier.uri | https://doi.org/10.1109/TELFOR.2018.8611906 | |
| dc.identifier.wos | WOS:000459714200041 | |
| dc.language.iso | en | en_US |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | en_US |
| dc.relation.ispartof | -- 26th Telecommunications Forum, TELFOR 2018 -- 2018-11-20 Through 2018-11-21 -- Belgrade -- 144370 | en_US |
| dc.relation.journal | 2018 26Th Telecommunications Forum (Telfor) | en_US |
| dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Band Selective E Measurements | en_US |
| dc.subject | Base Station | en_US |
| dc.subject | Electric Field Strength (E) | en_US |
| dc.subject | Electromagnetic Field | en_US |
| dc.subject | SRM-3006 | en_US |
| dc.title | Characterization of Indoor and Outdoor Electric Field Strength Levels at Hospitals | en_US |
| dc.type | Conference Object | en_US |
| dspace.entity.type | Publication |