Publication:
Characterization of Indoor and Outdoor Electric Field Strength Levels at Hospitals

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Research Projects

Organizational Units

Journal Issue

Abstract

In this study, electrical field strength (E) level measurements were conducted in indoor and outdoor at seven hospitals in the city center of Samsun/Turkey. E measurements were made with Narda SRM-3006 electromagnetic field meter, which can measure the frequency band between 30 MHz and 3 GHz selectively. Measurements results show that the highest E value within the hospital is 0.818 V/m, while this value is 2.627 V/m for out of hospital. The E exposed outdoor of the hospital is 2.93 times higher than indoor of the hospital for measurement locations. The main sources of total E in the environments are base stations, and their contributions are 92.5% and 98.6% for indoor and outdoor of the hospital respectively. The most contribution of 53.4% total E is base stations using 2100 MHz frequency. © 2018 IEEE.

Description

"Telekom Srbija" ad.; Ericsson; et al.; ETF - School of Electrical Engineering, University of Belgrade; Ministry of Trade, Turism and Telecommunications; Vlatacom d.o.o

Citation

WoS Q

Scopus Q

Source

-- 26th Telecommunications Forum, TELFOR 2018 -- 2018-11-20 Through 2018-11-21 -- Belgrade -- 144370

Volume

Issue

Start Page

164

End Page

167

Endorsement

Review

Supplemented By

Referenced By