Publication: Influence of Toothbrushing Methods on Tightening Torque with Healing Abutments of Different Lengths: An in Vitro Study
| dc.authorscopusid | 58954717300 | |
| dc.authorscopusid | 57192376389 | |
| dc.authorscopusid | 14046455100 | |
| dc.authorscopusid | 59179156900 | |
| dc.authorwosid | Kaleli, Necati/Gvu-0942-2022 | |
| dc.authorwosid | Şahin, Nurşen/Hsg-3967-2023 | |
| dc.contributor.author | Sahin, Nursen | |
| dc.contributor.author | Kaleli, Necati | |
| dc.contributor.author | Ural, Cagri | |
| dc.contributor.author | Ahmadli, Parvin | |
| dc.contributor.authorID | Şahin, Nurşen/0000-0001-7905-9977 | |
| dc.date.accessioned | 2025-12-11T01:09:32Z | |
| dc.date.issued | 2024 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Sahin, Nursen; Ural, Cagri] Giresun Univ, Fac Dent, Dept Prosthodont, Giresun, Turkiye; [Kaleli, Necati] Ondokuz Mayis Univ, Vocat Sch Hlth Serv, Dent Prosthesis Technol, Samsun, Turkiye | en_US |
| dc.description | Şahin, Nurşen/0000-0001-7905-9977; | en_US |
| dc.description.abstract | Statement of problem: Early tightening torque at the implant-healing abutment interface is a recognized concern in implant treatment. However, little is known regarding the effects of toothbrushing methods on the interface established between the implant and healing abutments of different heights. Purpose: The purpose of this in vitro study was to evaluate the effect of different toothbrushing methods on tightening torque for healing abutments of different heights. Material and methods: A total of 60 implants (Bilimplant; Proimtech) were embedded in epoxy resin blocks. The following 6 test groups were established: healing abutments with manual toothbrush group (Oral B Pro Expert All in one; Oral B) and 4 mm height (MTB-4, (which served as the control); 6 mm height (MTB-6, which served as the control); sonic toothbrush group (Philips Sonicare 3100 Series; Philips Oral Healthcare) and 4 mm height (S-4); 6 mm height (S-6); oscillating/rotating toothbrush group (Oral B Smart 6 6000N; Oral B) and 4 mm height (OR-4) and 6 mm height (OR-6). Each specimen was tightened to 15 Ncm and brushed. The digital torque meter (Cap Torque Tester Series TT01; Mark10) was used to calculate the reverse torque values. Results: The highest torque loss value in the average torque losses in the test groups was 1.3 (OR-6); the lowest was 0.3 (S-4). While a significant difference was found between groups S-4 and S-6 (P=.018), no statistically significant difference was found among the other groups (P>.05). Conclusions: Torque loss was greater in the healing abutment with a height of 6 mm and with the oscillatory and rotational brushing method. | en_US |
| dc.description.sponsorship | Scientific and Technological Research Council of Turkey | en_US |
| dc.description.sponsorship | Supported by the Scientific and Technological Research Council of Turkey (project no. 222S702) , Turkey. Necati Kaleli reports financial support was provided by Scientific and Technological Research Council of Turkey. If there are other authors, they declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. | en_US |
| dc.description.woscitationindex | Science Citation Index Expanded | |
| dc.identifier.doi | 10.1016/j.prosdent.2024.05.017 | |
| dc.identifier.endpage | 600000000 | en_US |
| dc.identifier.issn | 0022-3913 | |
| dc.identifier.issn | 1097-6841 | |
| dc.identifier.issue | 3 | en_US |
| dc.identifier.pmid | 38897844 | |
| dc.identifier.scopus | 2-s2.0-85196413287 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 6000 | en_US |
| dc.identifier.uri | https://doi.org/10.1016/j.prosdent.2024.05.017 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/41718 | |
| dc.identifier.volume | 132 | en_US |
| dc.identifier.wos | WOS:001313448600001 | |
| dc.identifier.wosquality | Q1 | |
| dc.language.iso | en | en_US |
| dc.publisher | Mosby-Elsevier | en_US |
| dc.relation.ispartof | Journal of Prosthetic Dentistry | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.title | Influence of Toothbrushing Methods on Tightening Torque with Healing Abutments of Different Lengths: An in Vitro Study | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |