Publication:
Influence of Toothbrushing Methods on Tightening Torque with Healing Abutments of Different Lengths: An in Vitro Study

dc.authorscopusid58954717300
dc.authorscopusid57192376389
dc.authorscopusid14046455100
dc.authorscopusid59179156900
dc.authorwosidKaleli, Necati/Gvu-0942-2022
dc.authorwosidŞahin, Nurşen/Hsg-3967-2023
dc.contributor.authorSahin, Nursen
dc.contributor.authorKaleli, Necati
dc.contributor.authorUral, Cagri
dc.contributor.authorAhmadli, Parvin
dc.contributor.authorIDŞahin, Nurşen/0000-0001-7905-9977
dc.date.accessioned2025-12-11T01:09:32Z
dc.date.issued2024
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Sahin, Nursen; Ural, Cagri] Giresun Univ, Fac Dent, Dept Prosthodont, Giresun, Turkiye; [Kaleli, Necati] Ondokuz Mayis Univ, Vocat Sch Hlth Serv, Dent Prosthesis Technol, Samsun, Turkiyeen_US
dc.descriptionŞahin, Nurşen/0000-0001-7905-9977;en_US
dc.description.abstractStatement of problem: Early tightening torque at the implant-healing abutment interface is a recognized concern in implant treatment. However, little is known regarding the effects of toothbrushing methods on the interface established between the implant and healing abutments of different heights. Purpose: The purpose of this in vitro study was to evaluate the effect of different toothbrushing methods on tightening torque for healing abutments of different heights. Material and methods: A total of 60 implants (Bilimplant; Proimtech) were embedded in epoxy resin blocks. The following 6 test groups were established: healing abutments with manual toothbrush group (Oral B Pro Expert All in one; Oral B) and 4 mm height (MTB-4, (which served as the control); 6 mm height (MTB-6, which served as the control); sonic toothbrush group (Philips Sonicare 3100 Series; Philips Oral Healthcare) and 4 mm height (S-4); 6 mm height (S-6); oscillating/rotating toothbrush group (Oral B Smart 6 6000N; Oral B) and 4 mm height (OR-4) and 6 mm height (OR-6). Each specimen was tightened to 15 Ncm and brushed. The digital torque meter (Cap Torque Tester Series TT01; Mark10) was used to calculate the reverse torque values. Results: The highest torque loss value in the average torque losses in the test groups was 1.3 (OR-6); the lowest was 0.3 (S-4). While a significant difference was found between groups S-4 and S-6 (P=.018), no statistically significant difference was found among the other groups (P>.05). Conclusions: Torque loss was greater in the healing abutment with a height of 6 mm and with the oscillatory and rotational brushing method.en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkeyen_US
dc.description.sponsorshipSupported by the Scientific and Technological Research Council of Turkey (project no. 222S702) , Turkey. Necati Kaleli reports financial support was provided by Scientific and Technological Research Council of Turkey. If there are other authors, they declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1016/j.prosdent.2024.05.017
dc.identifier.endpage600000000en_US
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.issue3en_US
dc.identifier.pmid38897844
dc.identifier.scopus2-s2.0-85196413287
dc.identifier.scopusqualityQ1
dc.identifier.startpage6000en_US
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2024.05.017
dc.identifier.urihttps://hdl.handle.net/20.500.12712/41718
dc.identifier.volume132en_US
dc.identifier.wosWOS:001313448600001
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherMosby-Elsevieren_US
dc.relation.ispartofJournal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleInfluence of Toothbrushing Methods on Tightening Torque with Healing Abutments of Different Lengths: An in Vitro Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files