Publication: Comparison of CBCT with Different Voxel Sizes and Intraoral Scanner for Detection of Periodontal Defects: An in Vitro Study
| dc.authorscopusid | 57053116100 | |
| dc.authorscopusid | 8502419700 | |
| dc.authorscopusid | 57217220783 | |
| dc.authorscopusid | 57202455423 | |
| dc.authorscopusid | 57216783998 | |
| dc.authorscopusid | 57197424517 | |
| dc.authorwosid | İçen, Murat/L-9627-2013 | |
| dc.authorwosid | Geduk, Gediz/Aag-3480-2020 | |
| dc.authorwosid | Cakmak Ozlu, Fethiye/Aan-2366-2021 | |
| dc.authorwosid | Şeker, Çiğdem/Khu-9023-2024 | |
| dc.authorwosid | Orhan, Kaan/I-4026-2019 | |
| dc.contributor.author | Icen, Murat | |
| dc.contributor.author | Orhan, Kaan | |
| dc.contributor.author | Seker, Cigdem | |
| dc.contributor.author | Geduk, Gediz | |
| dc.contributor.author | Ozlu, Fethiye Cakmak | |
| dc.contributor.author | Cengiz, Murat Inanc | |
| dc.contributor.authorID | Orhan, Kaan/0000-0001-6768-0176 | |
| dc.contributor.authorID | İçen, Murat/0000-0002-2779-5646 | |
| dc.date.accessioned | 2025-12-11T01:17:59Z | |
| dc.date.issued | 2020 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Icen, Murat] Nevsehir Haci Bektas Veli Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Nevsehir, Turkey; [Orhan, Kaan] Ankara Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Ankara, Turkey; [Seker, Cigdem; Geduk, Gediz] Zonguldak Bulent Ecevit Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Zonguldak, Turkey; [Ozlu, Fethiye Cakmak] Ondokuz Mayis Univ, Fac Dent, Dept Orthodont, Samsun, Turkey; [Cengiz, Murat Inanc] Zonguldak Bulent Ecevit Univ, Fac Dent, Dept Periodontol, Zonguldak, Turkey | en_US |
| dc.description | Orhan, Kaan/0000-0001-6768-0176; İçen, Murat/0000-0002-2779-5646; | en_US |
| dc.description.abstract | Objectives: This study aimed to compare the diagnostic accuracy of cone beam CT (CBCT) units with different voxel sizes with the digital intraoral scanning technique in terms of the detection of periodontal defects. Methods and materials: The study material comprised of 12 dry skulls with maxilla and mandible. Artificial defects were created on teeth separately using burs randomly on dry skulls. In total 46 dehiscences, 10 fenestrations, 17 furcations, 12 wall defects and 13 without periodontal defect were used in the study. Each tooth with and without defects was imaged at various vertical angles using each of the following modalities: a Veraviewepocs 3D R100 CBCT device and a 3D Shape TRIOS2E Color P13 Shade Intraoral Scanner. Results: The kappa values for interobserver agreement between observers ranged between 0.29 and 0.86 for the CBCT 10 x 8cm field of view (FOV) with 0,160 mm(3) voxel size; 0.35 and 1 for the CBCT 8 x 8cm FOV with 0,125 mm3 voxel size; and 0.30 and 1 of intraoral scans. The kappa values for detecting defects on anterior teeth were the least, following premolar and molar teeth both CBCT and intraoral scanning. Conclusions: Smaller voxel sizes and smaller CBCT FOV has the highest sensitivity and diagnostic accuracy for detecting various periodontal defects among the scanner modalities examined. Advances in knowledge: Adequate evaluation of the condition of the alveolar bone and periodontal tissues is important for the diagnosis, treatment, and prognosis of periodontal disease. Limited examination methods, such as palpation, inspection, and periodontal probe examination, may provide insufficient information for the diagnosis of periodontal diseases. | en_US |
| dc.description.woscitationindex | Science Citation Index Expanded | |
| dc.identifier.doi | 10.1259/dmfr.20190197 | |
| dc.identifier.issn | 0250-832X | |
| dc.identifier.issn | 1476-542X | |
| dc.identifier.issue | 5 | en_US |
| dc.identifier.pmid | 32134338 | |
| dc.identifier.scopus | 2-s2.0-85086793031 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.uri | https://doi.org/10.1259/dmfr.20190197 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/42673 | |
| dc.identifier.volume | 49 | en_US |
| dc.identifier.wos | WOS:000543299400005 | |
| dc.identifier.wosquality | Q1 | |
| dc.language.iso | en | en_US |
| dc.publisher | British Institute of Radiology | en_US |
| dc.relation.ispartof | Dentomaxillofacial Radiology | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Cone Beam CT | en_US |
| dc.subject | Alveolar Bone Loss | en_US |
| dc.subject | Furcation Defects | en_US |
| dc.title | Comparison of CBCT with Different Voxel Sizes and Intraoral Scanner for Detection of Periodontal Defects: An in Vitro Study | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
