Publication:
Yeni Tip Epoksi Matriks Voltametrik Elektrotların Geliştirilmesi; Ürik Asit, Askorbik Asit ve Dopamin Gibi Biyolojik Moleküllerin Tayinine Uygulanması

dc.contributor.advisorIşıldak, İbrahim
dc.contributor.authorŞaka, Tülin
dc.date.accessioned2020-07-21T21:36:22Z
dc.date.available2020-07-21T21:36:22Z
dc.date.issued2009
dc.departmentOMÜ, Fen Bilimleri Enstitüsü, Kimya Anabilim Dalıen_US
dc.departmentFen Bilimleri Enstitüsü / Kimya Ana Bilim Dalı
dc.descriptionTez (Doktora) -- Ondokuz Mayıs Üniversitesi, 2009en_US
dc.descriptionLibra Kayıt No: 58148en_US
dc.description.abstractBu çalışmada, dopamin (DA), askorbik asit (AA), ürik asit (ÜA) ve karışımlarının diferansiyel puls voltametrisi (DPV) ve dönüşümlü voltametri (CV) yöntemleri ile eş zamanlı tayini için grafit-polivinilklorür (PVC), grafit-polivinilkarboksilat (PVC-COOH), grafit-polivinilamonyum (PVC-NH2) ve grafit-polikarbonat (PC) kullanılmıştır.Dopaminin, 0,1M pH 7,4 fosfat tamponunda askorbik asit ve ürik asitin karışımlarındaki anodik piklerinin (ipa) iyi bir şekilde ayrılabildiği gözlenmiştir.Dopaminin voltametrik cevabı üzerinde etkili olan, pH, tarama hızı, tarama sayısı, tampon kapasitesi ve girişim etkisi gibi çeşitli deneysel parametreler araştırılmıştır.Genel olarak, optimum şartlar altında elde edilen kalibrasyon grafikleri üzerinden DA' nin doğrusal konsantrasyon aralığı 1,0x10-3?1,0x10-5 M olarak bulunmuştur. Kullanılan tüm elektrotlar için tayin limitleri 1,0x10-5-1,0x10-6 M arasında bulunmuştur. Elektrotlar, dopaminin tayini için tekrarlanabilirlik, seçicilik ve geri kazanılabilirlik gibi özellikleri yönünden karşılaştırılabilir analitik performans sergilediği belirlenmiştir.Modifiye edilmiş kompozit elektrotlar 0,1M pH 7,4 fosfat tamponunda ve insan kan plazmasında DA' nın tayini için uygulanmıştır.Elektrotlar dopamine hidroklorit (DHI) ilacında DA' nin tayini için uygulanmıştır.
dc.description.abstractIn this work, the composites of graphite?polyvinylchloride (PVC), graphite- polyvinylcarboxylate (PVC-COOH), graphite-polyvinylamonium (PVC-NH2) and graphite-polycarbonate (PC) were used as electrodes for the simultaneous detection of dopamine (DA), ascorbic acid (AA) and uric acid (UA) by differential pulse voltammetry (DPV) and cyclic voltammetry (CV) methods.The anodic peaks of, dopamine, ascorbic acid and uric acid in their mixture can be well separated in 0.1M phosphate buffer solution at pH 7.4.The effects of various experimental parameters such as the pH, scan rate, scan number, buffer capacity and interference on the voltammetric response of dopamine were investigated.Generally, under optimum conditions, linear calibration graphs were obtained over the DA concentration range to 1.0x10-3- 1.0x10-5M. The detection limits for dopamine were found to be 1.0x10-5-1.0x10-6M for all electrodes used. The electrodes showed good analytical performance characteristics corresponding repeatability, selectivity and recovery for the determination of DA.The modified composite electrodes have been applied for the assay of DA in phosphate buffer solution (0.1M pH 7.4) and human blood plasma samples.Electrodes were applied to determination of DA in Dopamine Hydrochloride (DBL) drug.en_US
dc.formatXXII, 208 y. : şekil ; 30 sm.en_US
dc.identifier.endpage236
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=ZeTyprYuef2HkaF3xt4wYuFyLspgsRLkKKC_BLS-iWK_nYAle_vRgd4NO7CeELsb
dc.identifier.urihttp://libra.omu.edu.tr/tezler/58148.pdf
dc.identifier.yoktezid260045
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Fen Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKimya
dc.subjectChemistryen_US
dc.subjectAskorbik Asit
dc.subjectAscorbic Aciden_US
dc.subjectDopamin
dc.subjectDopamineen_US
dc.subjectÜrik Asit
dc.subjectUric Aciden_US
dc.subject.otherTEZ DOK Ş159y 2009en_US
dc.titleYeni Tip Epoksi Matriks Voltametrik Elektrotların Geliştirilmesi; Ürik Asit, Askorbik Asit ve Dopamin Gibi Biyolojik Moleküllerin Tayinine Uygulanması
dc.titleDevelopment of New Type Epoxy Matrix Voltammetric Electrodes; Application at Determination of Biological Molecules Such as Ascorbic Acid, Uric Acid and Dopamineen_US
dc.typeDoctoral Thesisen_US
dspace.entity.typePublication

Files