Publication: Tamamıyla Katı-hal Kompozit Kalsiyum Seçici Elektrot ve Potansiyometrik Davranışı
| dc.contributor.advisor | Asan, Y.doç.dr. Adem | |
| dc.contributor.author | Sarıboğa, Nezaket | |
| dc.date.accessioned | 2020-07-21T21:39:41Z | |
| dc.date.available | 2020-07-21T21:39:41Z | |
| dc.date.issued | 2004 | |
| dc.department | OMÜ, Fen Bilimleri Enstitüsü, Kimya Anabilim Dalı | en_US |
| dc.department | Fen Bilimleri Enstitüsü / Kimya Ana Bilim Dalı | |
| dc.description | Tez (yüksek lisans) -- Ondokuz Mayıs Üniversitesi, 2004 | en_US |
| dc.description | Libra Kayıt No: 20878 | en_US |
| dc.description.abstract | 11 TAMAMIYLA KATI-HAL KOMPOZİT KALSİYUM SEÇİCİ ELEKTROT VE POTANSİYOMETRİK DAVRANIŞI ÖZET Bu çalışmada kalsiyum iyonofor IV (ETH 5234, N,N-Dicyclohexyl-N',N'-dioctadecyl- diglycolic daimide; N,N-Dicyclohexyl-N'-N'-dioctadecyl-3-oxapentanediamide) aktif maddesi kullanılarak tamamıyla katı-hal kompozit kalsiyum iyon-seçici elektrot hazırlandı. Elektrodun potansiyometrik performanslan bilgisayarlı bir ölçüm sisteminde araştırıldı. Hazırlanan bütünüyle katı hal kompozit kalsiyum iyon-seçici elektrodun ana iyon çözeltisine karşı her 1 0 kat konsantrasyon değişimi için 24 mV potansiyel değişimi gösterdiği, cevap zamanının oldukça kısa (yaklaşık 10 s) ve kullanım süresinin uzun (en az 8-10 hafta) olduğu belirlendi. Hazırlanan elektrot Ixl0_1-lxl0'5 mol.L'1 konsantrasyon aralığında ana iyon çözeltisine karşı doğrusal davranış sergilemekteydi. Elektrodun ana iyon yamnda girişim yapan iyonlara karşı seçicilik katsayıları 'ayrı çözelti metodu' ile hesaplandı ve kalsiyum iyonofor IV ile hazırlanan elektrodun özellikle Ca2+ iyonuna karşı oldukça seçici olduğu sonucuna varıldı. Ayrıca, geliştirilen elektrot, akış-enjeksiyon analiz (Fi A) sisteminde dedektör olarak kullanılarak çeşitli süt ve yoğurt örneklerindeki Ca2+ iyonunun tayini başarıyla gerçekleştirildi. Anahtar Kelimeler : İyon-Seçici Elektrot, Katı-Hal Elektrot, Kompozit elektrot, kalsiyum iyonofor IV, ETH 5234 | |
| dc.description.abstract | Ill ALL SOLID-STATE COMPOSITE CALCIUM SELECTIVE ELECTRODE AND ITS POTENTIOMETRIC PERFORMANCES ABSTRACT In this work, a solid-state composite calcium ion-selective electrode was prepared by using calcium ionophore IV (ETH 5234, N,N-Dicyclohexyl-N',N'-dioctadecyl-diglycolic daimide;N,N-Dicyclohexyl-N'-N'-dioctadecyl-3-oxapentanediamide). The potentiometric performance characteristics of the electrode was examined with a computerized measuring system. The prepared electrode almost exhibited 24 mV potential difference per decade, short response times (approximately 10 s), long life times (at least 8-10 week), a linear response between 1.10'1-1.10'5 mol.L'1 solutions against main ion. Selective cofficients of the electrodes for againts interfering ions were calculated by 'separate solution method' and while electrodes prepared with calcium ionophore IV compound showed very high selectivity toward Ca2+ ion. Besides, prepared electrode, used as dedector in flow-injection analyse (FIA) system in some milk and yogurt samples successfully. Keywords : Ion-Selective Electrode, Solid-State Electrode, Composite Electrode, Ca ionophore IV, ETH 5234 | en_US |
| dc.format | X, 63 y. : şekil, tablo. ; 30 sm. | en_US |
| dc.identifier.endpage | 73 | |
| dc.identifier.uri | http://libra.omu.edu.tr/tezler/20878.pdf | |
| dc.identifier.yoktezid | 155044 | |
| dc.language.iso | tr | en_US |
| dc.language.iso | tr | |
| dc.publisher | Ondokuz Mayıs Üniversitesi, Fen Bilimleri Enstitüsü | en_US |
| dc.relation.publicationcategory | Tez | en_US] |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Chemistry | en_US |
| dc.subject | Kimya | |
| dc.subject.other | TEZ YÜK LİS S245t 2004 | en_US |
| dc.title | Tamamıyla Katı-hal Kompozit Kalsiyum Seçici Elektrot ve Potansiyometrik Davranışı | |
| dc.title | All Solid-State Composite Calcium Selective Electrode and Its Potentiometric Performances | en_US |
| dc.type | Master Thesis | en_US |
| dspace.entity.type | Publication |