Basit öğe kaydını göster

dc.contributor.authorUzun, Ismail
dc.contributor.authorGunduz, Kaan
dc.contributor.authorCelenk, Peruze
dc.contributor.authorAvsever, Hakan
dc.contributor.authorOrhan, Kaan
dc.contributor.authorCanitezer, Gozde
dc.contributor.authorEgrioglu, Erol
dc.date.accessioned2020-06-21T13:45:59Z
dc.date.available2020-06-21T13:45:59Z
dc.date.issued2015
dc.identifier.issn1735-1065
dc.identifier.issn2008-2711
dc.identifier.urihttps://doi.org/10.5812/iranjradiol.18290
dc.identifier.urihttps://hdl.handle.net/20.500.12712/14220
dc.descriptionOrhan, Kaan/0000-0001-6768-0176; avsever, hakan/0000-0002-2972-2547; Egrioglu, Erol/0000-0003-4301-4149en_US
dc.descriptionWOS: 000360808600002en_US
dc.descriptionPubMed: 26557279en_US
dc.description.abstractBackground: The teeth with undiagnosed VRFs are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. Objectives: This study aimed to assess the use of different voxel resolutions of two different cone beam computerized tomography (CBCT) units in the detection of vertical root fractures (VRFs) in vitro. Materials and Methods: The study material comprised 74 extracted human mandibular single rooted premolar teeth without root fractures that had not undergone any root-canal treatment. Images were obtained by two different CBCT units. Four image sets were obtained as follows: 1) 3D Accuitomo 170, 4 x 4 cm field of view (FOV) (0.080 mm(3)); 2) 3D Accuitomo 170. 6 x 6 cm FOV (0.125 mm(3)); 3) NewTom 3G, 6 '' (0.16 mm(3)) and 4) NewTom 3G, 9 '' FOV (0.25 mm(3)). Kappa coefficients were calculated to assess both intra-and inter-observer agreements for each image set. Results: No significant differences were found among observers or voxel sizes, with high average Z (Az) results being reported for all groups. Both intra-and inter-observer agreement values were relatively better for 3D Accuitomo 170 images than the images from NewTom 3G. The highest Az and kappa values were obtained with 3D Accuitomo 170, 4 x 4 cm FOV (0.080 mm(3)) images. Conclusion: No significant differences were found among observers or voxel sizes, with high Az results reported for all groups.en_US
dc.language.isoengen_US
dc.publisherKowsar Publen_US
dc.relation.isversionof10.5812/iranjradiol.18290en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCone-Beam Computed Tomographyen_US
dc.subjectPermanent Dentitionen_US
dc.subjectDiagnosisen_US
dc.titleComparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teethen_US
dc.typearticleen_US
dc.contributor.departmentOMÜen_US
dc.identifier.volume12en_US
dc.identifier.issue3en_US
dc.relation.journalIranian Journal of Radiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster