Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth

Tarih

2015

Yazar

Uzun, Ismail
Gunduz, Kaan
Celenk, Peruze
Avsever, Hakan
Orhan, Kaan
Canitezer, Gozde
Egrioglu, Erol

Üst veri

Tüm öğe kaydını göster

Özet

Background: The teeth with undiagnosed VRFs are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. Objectives: This study aimed to assess the use of different voxel resolutions of two different cone beam computerized tomography (CBCT) units in the detection of vertical root fractures (VRFs) in vitro. Materials and Methods: The study material comprised 74 extracted human mandibular single rooted premolar teeth without root fractures that had not undergone any root-canal treatment. Images were obtained by two different CBCT units. Four image sets were obtained as follows: 1) 3D Accuitomo 170, 4 x 4 cm field of view (FOV) (0.080 mm(3)); 2) 3D Accuitomo 170. 6 x 6 cm FOV (0.125 mm(3)); 3) NewTom 3G, 6 '' (0.16 mm(3)) and 4) NewTom 3G, 9 '' FOV (0.25 mm(3)). Kappa coefficients were calculated to assess both intra-and inter-observer agreements for each image set. Results: No significant differences were found among observers or voxel sizes, with high average Z (Az) results being reported for all groups. Both intra-and inter-observer agreement values were relatively better for 3D Accuitomo 170 images than the images from NewTom 3G. The highest Az and kappa values were obtained with 3D Accuitomo 170, 4 x 4 cm FOV (0.080 mm(3)) images. Conclusion: No significant differences were found among observers or voxel sizes, with high Az results reported for all groups.

Kaynak

Iranian Journal of Radiology

Cilt

12

Sayı

3

Bağlantı

https://doi.org/10.5812/iranjradiol.18290
https://hdl.handle.net/20.500.12712/14220

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.