• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

An Alternative Prosthetic Approach for Rehabilitation of Two Edentulous Maxillectomy Patients: Clinical Report

Tarih

2017

Yazar

Yenisey, Murat
Kulunk, Safak
Kaleli, Necati

Üst veri

Tüm öğe kaydını göster

Özet

Obturator prosthesis is a common treatment method for maxillectomy patients for maintaining their oronasal separation and resuming their social lives. After tumor resection, the remaining anatomical structures have a significant effect on prosthesis retention. The present study describes the rehabilitation of two maxillectomy patients after cancer surgery using a prosthesis consisting of a denture and a special retentive obturator that is positioned in the anatomical undercuts of the nasal cavity. These patients have undergone total and subtotal maxillectomy surgery after the diagnosis of squamous cell carcinoma. The systemic and local health status of the total maxillectomy patient was not suitable for zygomatic implant surgery. Only one osseointegrated dental implant was placed into the left maxillary tuberosity area in the subtotal maxillectomy patient. In addition, the quality, vertical height, and horizontal width of the remaining bone structures in the maxilla limited the use of osseointegrated dental implants. Mechanical prosthesis retention was provided using a multiunit retentive mechanism composed of an orthodontic forsus fatigue resistant device (OFFRD), two Herbst appliances, and an acrylic piece associated with healthy keratinized mucosa. The OFFRD could easily apply a consistent force and push the acrylic pieces toward the retentive undercut under the control of the two Herbst appliances. Two OFFRD units in different directions were designed for the total maxillectomy patient, while only one OFFRD unit was placed on the opposite side of the osseointegrated implant in the subtotal maxillectomy patient. A sufficient retention was obtained for both patients. The patients were satisfied, and no major complications were observed in periodic controls.

Kaynak

Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry

Cilt

26

Sayı

5

Bağlantı

https://doi.org/10.1111/jopr.12617
https://hdl.handle.net/20.500.12712/12394

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.