Comparison of central corneal thickness measurements using different imaging devices and ultrasound pachymetry

Tarih

2019

Yazar

Can, Ertugrul
Eser-Ozturk, Hilal
Duran, Mustafa
Cetinkaya, Tugba
Ariturk, Nursen

Üst veri

Tüm öğe kaydını göster

Özet

To compare central corneal thickness (CCT) measurements obtained by the AL-Scan, Lenstar LS900, Galilei, and ultrasound pachymetry (UP) in normal and cataractous eyes. Methods: Eighty eyes of healthy subjects were included in the study. Each subject was assessed by four different methods of measurements using the AL-Scan, Lenstar LS900, Galilei, and UP by a single examiner. To assess the intraobserver repeatability, three consecutive measurements were taken for the AL-Scan. Results: The mean CCT [+/- standard deviation (SD)] for the AL-Scan, Lenstar LS900, Galilei, and UP were 554.6 +/- 30.9 mu m, 542.9 +/- 31.3 mu m, 570.7 +/- 30 mu m, and 552.7 +/- 32.8 mu m, respectively. The differences between pairs of mean CCT for the methods are statistically significant for the pairs of Galilei-UP, AL-Scan-Galilei, and Lenstar LS900-Galilei. Bland-Altman plots showed that AL-Scan-UP have the closest agreement, followed by Lenstar-UP and AL-Scan-Lenstar. Galilei was found to have the poorest agreement with the other three methods. The intraobserver repeatability of the AL-Scan was very good with an intraclass correlation coefficient (ICC) of 0.980. Conclusion: We found that CCT measurements between the AL-Scan-UP, Lenstar LS900-UP, and AL-Scan-Lenstar LS900 showed very strong correlation and comparable agreement. AL-Scan-UP showed the closest agreement and these devices can be used interchangeably in clinical practice. Galilei significantly showed higher value of CCT compared to other methods. It was also observed that the Al-Scan had excellent intraobserver repeatability.

Kaynak

Indian Journal of Ophthalmology

Cilt

67

Sayı

4

Bağlantı

https://doi.org/10.4103/ijo.IJO_960_18
https://hdl.handle.net/20.500.12712/10912

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.