Publication:
Comprehensive Analysis of Magnetic Flux Density and RF-EMF Exposure in Electric Buses: A Case Study From Samsun, Turkey

dc.authorscopusid58034083600
dc.authorscopusid16230640200
dc.authorscopusid36092815900
dc.authorscopusid56459776800
dc.authorwosidCheema, Adnan Ahmad/Isu-3128-2023
dc.authorwosidKaradag, Teoman/Abg-7723-2020
dc.authorwosidKurnaz, Cetin/S-3469-2016
dc.authorwosidAlbayrak, Zafer/Oaj-6102-2025
dc.contributor.authorAlbayrak, Zafer Emre
dc.contributor.authorKurnaz, Cetin
dc.contributor.authorKaradag, Teoman
dc.contributor.authorCheema, Adnan Ahmad
dc.contributor.authorIDKaradag, Teoman/0000-0002-7682-7771
dc.contributor.authorIDKurnaz, Cetin/0000-0003-3436-899X
dc.date.accessioned2025-12-11T01:19:24Z
dc.date.issued2024
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Albayrak, Zafer Emre] Samsun Metropolitan Municipal, Dept Publ Works, Mech Elect & Lighting Branch, TR-55200 Samsun, Turkiye; [Kurnaz, Cetin] Ondokuz Mayis Univ, Dept Elect & Elect Engn, TR-55139 Samsun, Turkiye; [Karadag, Teoman] Inonu Univ, Dept Elect & Elect Engn, TR-44280 Malatya, Turkiye; [Cheema, Adnan Ahmad] Ulster Univ, Sch Engn, Belfast BT15 1AP, North Irelanden_US
dc.descriptionKaradag, Teoman/0000-0002-7682-7771; Kurnaz, Cetin/0000-0003-3436-899X;en_US
dc.description.abstractThis study investigates magnetic flux density (B) and radiofrequency electromagnetic field (RF-EMF) measurements on electric buses operating in Samsun, Turkey, focusing on two bus routes (called E1 and E4) during the morning and evening hours. Measurements were taken under diverse operational conditions, including acceleration, cruising, and braking, at locations of peak passenger density. Along the E1 route, the magnetic field intensity varied significantly based on the bus position, road slope, and passenger load, with notable increases during braking. In contrast, the E4 route showed a lower magnetic field intensity and RF-EMF values due to its straighter trajectory and reduced operational stops. The highest RF-EMF measurement recorded was 6.01 V/m, which is below the maximum levels established by the ICNIRP guidelines. In 11 out of the 12 different band-selective RF-EMF measurements, the highest contribution came from the downlink band of the base stations, while in only one measurement, the highest contribution originated from the uplink bands of the base stations. All data were subject to the Anderson-Darling test, confirming the generalized extreme value distribution as the best fit for both B and RF-EMF measurements. Additionally, the study assessed B levels inside and outside the bus during charging, revealing heightened readings near the pantograph. These findings significantly contribute to our understanding of electromagnetic field exposure in electric bus environments, highlighting potential health implications and informing the development of targeted mitigation strategies.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.3390/s24175634
dc.identifier.issn1424-8220
dc.identifier.issue17en_US
dc.identifier.pmid39275545
dc.identifier.scopus2-s2.0-85203879556
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.3390/s24175634
dc.identifier.urihttps://hdl.handle.net/20.500.12712/42850
dc.identifier.volume24en_US
dc.identifier.wosWOS:001311383900001
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.relation.ispartofSensorsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMagnetic Flux Densityen_US
dc.subjectRadiofrequency Electromagnetic Fielden_US
dc.subjectElectric Busesen_US
dc.subjectPublic Transportationen_US
dc.subjectPersonal Exposureen_US
dc.subjectHealth Risksen_US
dc.subjectICNIRPen_US
dc.titleComprehensive Analysis of Magnetic Flux Density and RF-EMF Exposure in Electric Buses: A Case Study From Samsun, Turkeyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files