Publication:
The Effect of pH-Cycling and Toothbrushing Simulations on Surface Roughness of Bulk-Fill Composites

dc.authorwosidBal, Lena/Hkm-9580-2023
dc.contributor.authorGönülol, Nihan
dc.contributor.authorAlmasifar, Lena
dc.contributor.authorMisilli, Tuğba
dc.contributor.authorÇabadağ, Özge Gizem
dc.contributor.authorDinç, Derya
dc.contributor.authorMisilli, Tugba
dc.contributor.authorGonulol, Nihan
dc.contributor.authorCabadag, Ozge Gizem
dc.contributor.authorAlmasifar, Lena
dc.contributor.authorDinc, Derya
dc.contributor.authorID0000-0002-7046-7154en_US
dc.contributor.authorID0000-0003-3493-0137en_US
dc.contributor.authorIDBal, Lena/0000-0003-3493-0137
dc.contributor.authorIDYenidünya, Özge Gizem/0000-0001-7898-9259
dc.contributor.authorIDGönülol, Ni̇han/0000-0002-7046-7154
dc.date.accessioned2022-09-06T12:20:18Z
dc.date.available2022-09-06T12:20:18Z
dc.date.issued2021
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Misilli, Tugba] Canakkale Onsekiz Mart Univ, Dept Restorat Dent, Fac Dent, Canakkale, Turkey; [Gonulol, Nihan; Almasifar, Lena] Ondokuz Mayis Univ, Dept Restorat Dent, Fac Dent, Samsun, Turkey; [Cabadag, Ozge Gizem] Pamukkale Univ, Dept Restorat Dent, Fac Dent, Denizli, Turkey; [Dinc, Derya] Konya Oral & Dent Hlth Hosp, Konya, Turkeyen_US
dc.descriptionESCI
dc.descriptionBal, Lena/0000-0003-3493-0137; Yenidünya, Özge Gizem/0000-0001-7898-9259; Gönülol, Ni̇han/0000-0002-7046-7154;en_US
dc.description.abstractObjective: This study aimed to compare surface roughness values (Ra) of different posterior composites after pH-cycling and toothbrushing simulation. Methods: Fifty disc-shaped specimens (8x2 mm) were prepared by using three bulk-fill composites [Filtek Bulk Fill Posterior (FBF), SonicFill 2 (SF), X-tra fil (XF)], a flowable [G-aenial Universal Flo (GF)], and a microhybrid composite [Filtek Z250 (Z250)]. After initial roughness (Ra0) measurements were performed with a contact profilometer, the samples were subjected to a pH-cycling model for 10 days and Ra1 values were recorded. Then, the samples were subjected to toothbrushing simulation for 4 min and final values (Ra2) were recorded. From each group, a representative sample was analyzed with an optical profilometer. The values were analyzed by two-way ANOVA with repeated measures on one factor (period) followed by Tukey's test (p<0.05). Results: Significant differences were found among materials regardless of experimental periods. The lowest Ra values were determined in GF and Z250 groups. The highest value was obtained in SF, but this value was not statistically significant different from that obtained in XF group. Brushing procedure after chemical degradation led to an increase in surface roughness of all materials except FBF, which was not statistically significant. Conclusion: While Ra values showed differences depending on the materials, pH-cycling and toothbrushing simulation did not have a significant effect on these values.en_US
dc.description.woscitationindexEmerging Sources Citation Index
dc.identifier.citationMİSİLLİ T,GÖNÜLO N,CABADAĞ Ö. G,ALMASİFAR L,DİNÇ D (2021). The Effect of Ph-cycling and Toothbrushing Simulations on Surface Roughness of Bulk-Fill Composites. Clinical and Experimental Health Sciences, 11(3), 487 - 494. Doi: 10.33808/clinexphealthsci.818099.en_US
dc.identifier.doi10.33808/clinexphealthsci.818099
dc.identifier.endpage494en_US
dc.identifier.issn2459-1459
dc.identifier.issn2459-1459
dc.identifier.issue3en_US
dc.identifier.startpage487en_US
dc.identifier.trdizinid481075
dc.identifier.urihttps://doi.org/10.33808/clinexphealthsci.818099
dc.identifier.urihttps://doi.org/10.33808/clinexphealthsci.818099
dc.identifier.urihttps://search.trdizin.gov.tr/en/yayin/detay/481075/the-effect-of-ph-cycling-and-toothbrushing-simulations-on-surface-roughness-of-bulk-fill-composites
dc.identifier.urihttps://hdl.handle.net/20.500.12712/33435
dc.identifier.volume11en_US
dc.identifier.wosWOS:000706782100017
dc.institutionauthorGönülol, Nihan
dc.institutionauthorAlmasifar, Lena
dc.language.isoenen_US
dc.publisherMarmara Univ, Inst Health Sciencesen_US
dc.relation.ispartofClinical and Experimental Health Sciencesen_US
dc.relation.journalClinical and Experimental Health Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBulk-Fillsen_US
dc.subjectpH-Cyclingen_US
dc.subjectResin-Based Compositesen_US
dc.subjectSurface Roughnessen_US
dc.subjectToothbrushingen_US
dc.titleThe Effect of pH-Cycling and Toothbrushing Simulations on Surface Roughness of Bulk-Fill Compositesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
84a0c45e-5c9d-41b3-82bf-018c51cb1a0c.pdf
Size:
2.3 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: