Publication: Using Magnetic Resonance Images for Organ and Region Volume Estimation
| dc.authorscopusid | 57741734000 | |
| dc.authorscopusid | 26425788700 | |
| dc.authorscopusid | 57054834700 | |
| dc.authorscopusid | 57195678013 | |
| dc.authorscopusid | 58561902300 | |
| dc.authorscopusid | 7403238396 | |
| dc.contributor.author | Bakirhan, E.G. | |
| dc.contributor.author | Deniz, Ö.G. | |
| dc.contributor.author | Kaplan, A.A. | |
| dc.contributor.author | Alkan, I. | |
| dc.contributor.author | Tüfekci, K.K. | |
| dc.contributor.author | Kaplan, S. | |
| dc.date.accessioned | 2025-12-11T00:32:38Z | |
| dc.date.issued | 2024 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Bakirhan] Elfide Gizem, Department of Histology and Embryology, Adiyaman Üniversitesi, Adiyaman, Adiyaman, Turkey; [Deniz] Ömür Gülsüm, Department of Histology and Embryology, Abant Izzet Baysal University, Faculty of Medicine, Bolu, Turkey; [Kaplan] Arife Ahsen, Department of Histology and Embryology, İstanbul Medipol Üniversitesi, Istanbul, Beykoz, Turkey; [Alkan] Işinsu, Department of Basic Sciences, Nevşehir Haci Bektaş Veli Üniversitesi, Nevsehir, Turkey; [Tüfekci̇] Kıymet Kübra, Department of Histology and Embryology, Kastamonu University, Kastamonu, Kastamonu, Turkey; [Kaplan] Süleyman, Department of Histology and Embryology, Ondokuz Mayis University, Medical School, Samsun, Turkey | en_US |
| dc.description.abstract | The examination of magnetic resonance (MR) images in clinical research is important for the analysis of disease images and diseases. Organ and region volume measurements are of great importance in the diagnosis of various diseases. For volume estimation, MR images are both inexpensive and easy to obtain and involve a non-hazardous method. Medical software tools are being developed to assist clinicians, surgeons and researchers in their computer-aided research projects. Currently available MR image segmentation tools differ widely from one another in terms of design, functionality and accessibility. This chapter discusses and describes the different medical software tools developed for manual, semi-automatic or fully automatic volumetric evaluation from MR images and some of the features of these tools. Brief information about the leading MR image segmentation software in clinical research is provided, and these software tools are introduced. © 2024 Nova Science Publishers, Inc. All rights reserved. | en_US |
| dc.identifier.endpage | 150 | en_US |
| dc.identifier.isbn | 9798891138940 | |
| dc.identifier.isbn | 9798891137707 | |
| dc.identifier.scopus | 2-s2.0-85201345026 | |
| dc.identifier.startpage | 141 | en_US |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/37239 | |
| dc.language.iso | en | en_US |
| dc.publisher | Nova Science Publishers, Inc. | en_US |
| dc.relation.publicationcategory | Kitap Bölümü - Uluslararası | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Cavalieri | en_US |
| dc.subject | Imagej | en_US |
| dc.subject | Magnetic Resonance (Mr) | en_US |
| dc.subject | Osirix | en_US |
| dc.subject | Stereology | en_US |
| dc.title | Using Magnetic Resonance Images for Organ and Region Volume Estimation | en_US |
| dc.type | Book Part | en_US |
| dspace.entity.type | Publication |
