Publication:
Mamografik İncelemelerde Meme Yapısının Meme Organ Dozuna Etkileri

dc.contributor.advisorBayrak, İlkay Koray
dc.contributor.authorBulğan, Orhan
dc.date.accessioned2020-07-21T21:47:32Z
dc.date.available2020-07-21T21:47:32Z
dc.date.issued2014
dc.departmentOMÜ, Sağlık Bilimleri Enstirüsü, Radyolojik Bilimler Anabilim Dalıen_US
dc.departmentSağlık Bilimleri Enstitüsü / Radyolojik Bilimler Ana Bilim Dalı
dc.descriptionTez (yüksek lisans) -- Ondokuz Mayıs Üniversitesi, 2014en_US
dc.descriptionLibra Kayıt No: 109561en_US
dc.description.abstractMEMEDE KOMPRESYON ETKİSİ Amaç: Meme görüntülemesinde gelişmeye yönelik tüm çalışmalar, meme kanserinin erken tanısına katkıda bulunmayı ve bunu yaparken hastalara verilebilecek olası zararın minimal olmasını amaçlamaktadır. Glandüler doz, 4,5 cm kalınlıkta komprese edilmiş, %50 glandüler doku, %50 yağ doku paternindeki bir meme için 3,0 mGy'den az olmalıdır. Materyal ve Metot: Çalışmada Ondokuz Mayıs Üniversitesi Tıp Fakültesi Radyoloji Anabilim Dalı mamografi bölümüne Şubat 2014 tarihinde başvuran ve standart pozisyon olan kraniokaudal (CC) ve mediolateral oblik (MLO) grafiler ile meme görüntülemesi yapılan 100 hastanın sol memesine ait görüntüler kullanılmıştır. Osirix adlı DICOM görüntüleme programında açılan mamografik görüntülerde memenin, glandüler dokunun ve pektoral kasın görüntüde kapladığı alan ilgi alanı çizilerek cm² olarak ölçüldü. Memenin bu yapısal bilgileri ile kompresyon basıncı ve kalınlığı yine cihaz programı üzerinden öğrenilen organ dozu ile karşılaştırıldı. Bulgular: Meme glandüler dozunu belirleyen parametreler arasında komprese meme kalınlığı en önemli parametre olarak tespit edilmiştir. Memede glandüler yapının kapladığı alan, bu alanın memenin görüntülerde kapladığı alana oranı ve memenin görüntülerde kapladığı alan kompresyon kalınlığına oranla glandüler doz ile daha az ilişkilidir. Meme glandüler konfigürasyonunun BI-RADS'a göre sınıflandırılması ile elde edilen 4 kategorinin dozla korelasyonu ölçümler yapılarak değerlendirilmesi kadar güçlü değildir. Sonuç: Mamografik görüntüleme yapılan hastanın grafi başına aldığı meme glandüler dozu kompresyon kalınlığı, glandüler dokunun memede kapsadığı alan ve bu alanın meme alanına oranı ölçülerek öngörülebilir. Sık aralıklı takiplere ya da alınacak ek grafilerde glandüler doz hakkında yaklaşık bilgi sahibi olunması bu kararların verilmesi aşamasında önemli olacaktır.
dc.description.abstractBREAST COMPRESSION EFFECT Aim: All studies that improve breast imaging is done in order to diagnose malignancies early by using as low glandular dose as possible to lower potential harms to the patient. Glandular dose must be lower than 3.0 mGy in 50% glandular, 50% fatty breast with 4.5 compression thickness. Material and Method: Standard left craniocaudal (CC) and mediolateral oblique (MLO) mammography of 100 patients applied in February 2014 included in the study. The information of compression thickness, compression pressure, exposure, entrance dose and glandular dose was noted both for CC and MLO views from the report computer of mammography machine. The images transferred to the DICOM viewer program called Osirix. The area of breast, glandular tissue and pectoral muscle comprise in the whole image was measured in cm². These architectural data of breast, compression thickness and the pressure was compared with the glandular dose. Results: Among the parameters that determine glandular dose, compression thickness was established as the most important parameter. The glandular area, rate for the glandular are to the whole breast area, area of the breast in mammography were correlated with glandular dose lower than the compression thickness. The correlations of 4 categories of glandular composition classified according to the BI-RADS lexicon were not as strong as the measurements described above. Conclusion: The glandular dose in the patient to whom breast imaging was done can be estimated by evaluating compression thickness, the area of the glandular tissue in the breast and the rate of this area to the whole breast area. The information of the approximate glandular dose in one view can be important in deciding short follow up or taking additional views.en_US
dc.formatIX, 74 y. : şekil, tablo ; 30 sm.en_US
dc.identifier.endpage84
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=Br_XTptK8CZ70f0JGX9xElMtHOJOdywumbFTPaS4I8McE0xABpIsF_3XGT5-CQCb
dc.identifier.urihttp://libra.omu.edu.tr/tezler/109561.pdf
dc.identifier.yoktezid427151
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Sağlık Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectRadyoloji ve Nükleer Tıp
dc.subjectDoz-Cevap İlişkisi-Radyasyon
dc.subjectMamografi
dc.subjectMeme
dc.subjectMeme Hastalıkları
dc.subjectRadyasyon
dc.subjectRadyasyon Dozajı
dc.subjectRadiology and Nuclear Medicineen_US
dc.subjectRadyasyon Etkileri
dc.subjectDose-Response Relationship-Radiationen_US
dc.subjectRadyografi
dc.subjectMammographyen_US
dc.subjectRadyometri
dc.subjectBreasten_US
dc.subjectBreast Diseasesen_US
dc.subjectRadiationen_US
dc.subjectRadiation Dosageen_US
dc.subjectRadiation Effectsen_US
dc.subjectRadiographyen_US
dc.subjectRadiometryen_US
dc.subject.otherTEZ YÜK LİS B933m 2014en_US
dc.titleMamografik İncelemelerde Meme Yapısının Meme Organ Dozuna Etkileri
dc.titleMammographic Views of the Breast Structure Effects on Mammary Organ Dosesen_US
dc.typeMaster Thesisen_US
dspace.entity.typePublication

Files