Publication:
Measurement of Attenuation Coefficients for Bone, Muscle, Fat and Water at 140, 364 and 662 keV Gamma-Ray Energies

dc.authorscopusid37121437600
dc.authorscopusid6505854341
dc.authorscopusid8599845000
dc.authorscopusid55887283900
dc.authorscopusid6506631141
dc.contributor.authorAkar, A.
dc.contributor.authorBaltaş, H.
dc.contributor.authorÇevik, U.
dc.contributor.authorKorkmaz, F.
dc.contributor.authorOkumuşoĝlu, N.T.
dc.date.accessioned2020-06-21T15:25:09Z
dc.date.available2020-06-21T15:25:09Z
dc.date.issued2006
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Akar] Ayşegül K., Department of Physics, Ondokuz Mayis University Faculty of Science and Arts, Samsun, Turkey; [Baltaş] Hasan, Department of Physics, Karadeniz Technical University, Trabzon, Trabzon, Turkey; [Çevik] Uǧur ̌ur, Department of Physics, Karadeniz Technical University, Trabzon, Trabzon, Turkey; [Korkmaz] Filiz, Department of Physics, Karadeniz Technical University, Trabzon, Trabzon, Turkey; [Okumuşoĝlu] Nazmi Turan, Department of Physics, Ondokuz Mayis University Faculty of Science and Arts, Samsun, Turkeyen_US
dc.description.abstractThe half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662 keV γ-ray energies by using the ATOMLABTM-930 medical spectrometer. The γ-rays were obtained from 99mTc, 131I and 137Cs γ-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001 keV-20 MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement. © 2006 Elsevier Ltd. All rights reserved.en_US
dc.identifier.doi10.1016/j.jqsrt.2006.02.007
dc.identifier.endpage211en_US
dc.identifier.issn0022-4073
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-33746804628
dc.identifier.scopusqualityQ2
dc.identifier.startpage203en_US
dc.identifier.urihttps://doi.org/10.1016/j.jqsrt.2006.02.007
dc.identifier.volume102en_US
dc.identifier.wosWOS:000240641200008
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.ispartofJournal of Quantitative Spectroscopy & Radiative Transferen_US
dc.relation.journalJournal of Quantitative Spectroscopy & Radiative Transferen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAttenuation Coefficienten_US
dc.subjectHalf-Value Thicknessen_US
dc.subjectRadioactivityen_US
dc.titleMeasurement of Attenuation Coefficients for Bone, Muscle, Fat and Water at 140, 364 and 662 keV Gamma-Ray Energiesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files