Publication: Measurement of Attenuation Coefficients for Bone, Muscle, Fat and Water at 140, 364 and 662 keV Gamma-Ray Energies
| dc.authorscopusid | 37121437600 | |
| dc.authorscopusid | 6505854341 | |
| dc.authorscopusid | 8599845000 | |
| dc.authorscopusid | 55887283900 | |
| dc.authorscopusid | 6506631141 | |
| dc.contributor.author | Akar, A. | |
| dc.contributor.author | Baltaş, H. | |
| dc.contributor.author | Çevik, U. | |
| dc.contributor.author | Korkmaz, F. | |
| dc.contributor.author | Okumuşoĝlu, N.T. | |
| dc.date.accessioned | 2020-06-21T15:25:09Z | |
| dc.date.available | 2020-06-21T15:25:09Z | |
| dc.date.issued | 2006 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Akar] Ayşegül K., Department of Physics, Ondokuz Mayis University Faculty of Science and Arts, Samsun, Turkey; [Baltaş] Hasan, Department of Physics, Karadeniz Technical University, Trabzon, Trabzon, Turkey; [Çevik] Uǧur ̌ur, Department of Physics, Karadeniz Technical University, Trabzon, Trabzon, Turkey; [Korkmaz] Filiz, Department of Physics, Karadeniz Technical University, Trabzon, Trabzon, Turkey; [Okumuşoĝlu] Nazmi Turan, Department of Physics, Ondokuz Mayis University Faculty of Science and Arts, Samsun, Turkey | en_US |
| dc.description.abstract | The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662 keV γ-ray energies by using the ATOMLABTM-930 medical spectrometer. The γ-rays were obtained from 99mTc, 131I and 137Cs γ-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001 keV-20 MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement. © 2006 Elsevier Ltd. All rights reserved. | en_US |
| dc.identifier.doi | 10.1016/j.jqsrt.2006.02.007 | |
| dc.identifier.endpage | 211 | en_US |
| dc.identifier.issn | 0022-4073 | |
| dc.identifier.issue | 2 | en_US |
| dc.identifier.scopus | 2-s2.0-33746804628 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 203 | en_US |
| dc.identifier.uri | https://doi.org/10.1016/j.jqsrt.2006.02.007 | |
| dc.identifier.volume | 102 | en_US |
| dc.identifier.wos | WOS:000240641200008 | |
| dc.identifier.wosquality | Q2 | |
| dc.language.iso | en | en_US |
| dc.publisher | Pergamon-Elsevier Science Ltd | en_US |
| dc.relation.ispartof | Journal of Quantitative Spectroscopy & Radiative Transfer | en_US |
| dc.relation.journal | Journal of Quantitative Spectroscopy & Radiative Transfer | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Attenuation Coefficient | en_US |
| dc.subject | Half-Value Thickness | en_US |
| dc.subject | Radioactivity | en_US |
| dc.title | Measurement of Attenuation Coefficients for Bone, Muscle, Fat and Water at 140, 364 and 662 keV Gamma-Ray Energies | en_US |