Publication:
Preconcentration of Cu(II), Cd(II) and Pb(II) on Amberlite XAD-4 Resin Functionalized With N,N′-Bis(o and Their Determination by FAAS in Water Samples

dc.authorscopusid20733997400
dc.authorscopusid36676149800
dc.authorscopusid6602726308
dc.contributor.authorEfendioǧlu, A.
dc.contributor.authorYaǧan Aşci, M.
dc.contributor.authorBati, B.
dc.date.accessioned2020-06-21T14:46:36Z
dc.date.available2020-06-21T14:46:36Z
dc.date.issued2010
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Efendioǧlu] Ayşegül, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Yaǧan Aşci] Mehtap, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Bati] Bekir, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA new polystyrene divinylbenzene-based chelating resin was synthesized by functionalizing Amberlite XAD-4 with N,N′-bis(o-vanillinidene)ethylenediamine. This resin was capable of preconcentrating Cu(II), Cd(II) and Pb(II) in water samples prior to FAAS determination. Various parameters, such as the pH, eluent type and concentration, volume of the eluent and the sample, and diverse ion effects have been studied. The recoveries for the analytes under the optimum working conditions were higher than 95%. The accuracy of the method was tested with standard reference materials (MBH-C31XB20, GBW-02703 and CRM BCR-32) and Cd(II), Cu(II) and Pb(II) standard solutions. The method was successfully applied to water samples. © 2010 The Japan Society for Analytical Chemistry.en_US
dc.identifier.doi10.2116/analsci.26.1283
dc.identifier.endpage1288en_US
dc.identifier.issn0910-6340
dc.identifier.issn1348-2246
dc.identifier.issue12en_US
dc.identifier.pmid21157098
dc.identifier.scopus2-s2.0-78650084965
dc.identifier.scopusqualityQ3
dc.identifier.startpage1283en_US
dc.identifier.urihttps://doi.org/10.2116/analsci.26.1283
dc.identifier.volume26en_US
dc.identifier.wosWOS:000285742100012
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherJapan Society for Analytical Chemistryen_US
dc.relation.ispartofAnalytical Sciencesen_US
dc.relation.journalAnalytical Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titlePreconcentration of Cu(II), Cd(II) and Pb(II) on Amberlite XAD-4 Resin Functionalized With N,N′-Bis(o and Their Determination by FAAS in Water Samplesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files