Publication: Preconcentration of Cu(II), Cd(II) and Pb(II) on Amberlite XAD-4 Resin Functionalized With N,N′-Bis(o and Their Determination by FAAS in Water Samples
| dc.authorscopusid | 20733997400 | |
| dc.authorscopusid | 36676149800 | |
| dc.authorscopusid | 6602726308 | |
| dc.contributor.author | Efendioǧlu, A. | |
| dc.contributor.author | Yaǧan Aşci, M. | |
| dc.contributor.author | Bati, B. | |
| dc.date.accessioned | 2020-06-21T14:46:36Z | |
| dc.date.available | 2020-06-21T14:46:36Z | |
| dc.date.issued | 2010 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Efendioǧlu] Ayşegül, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Yaǧan Aşci] Mehtap, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Bati] Bekir, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | A new polystyrene divinylbenzene-based chelating resin was synthesized by functionalizing Amberlite XAD-4 with N,N′-bis(o-vanillinidene)ethylenediamine. This resin was capable of preconcentrating Cu(II), Cd(II) and Pb(II) in water samples prior to FAAS determination. Various parameters, such as the pH, eluent type and concentration, volume of the eluent and the sample, and diverse ion effects have been studied. The recoveries for the analytes under the optimum working conditions were higher than 95%. The accuracy of the method was tested with standard reference materials (MBH-C31XB20, GBW-02703 and CRM BCR-32) and Cd(II), Cu(II) and Pb(II) standard solutions. The method was successfully applied to water samples. © 2010 The Japan Society for Analytical Chemistry. | en_US |
| dc.identifier.doi | 10.2116/analsci.26.1283 | |
| dc.identifier.endpage | 1288 | en_US |
| dc.identifier.issn | 0910-6340 | |
| dc.identifier.issn | 1348-2246 | |
| dc.identifier.issue | 12 | en_US |
| dc.identifier.pmid | 21157098 | |
| dc.identifier.scopus | 2-s2.0-78650084965 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 1283 | en_US |
| dc.identifier.uri | https://doi.org/10.2116/analsci.26.1283 | |
| dc.identifier.volume | 26 | en_US |
| dc.identifier.wos | WOS:000285742100012 | |
| dc.identifier.wosquality | Q3 | |
| dc.language.iso | en | en_US |
| dc.publisher | Japan Society for Analytical Chemistry | en_US |
| dc.relation.ispartof | Analytical Sciences | en_US |
| dc.relation.journal | Analytical Sciences | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.title | Preconcentration of Cu(II), Cd(II) and Pb(II) on Amberlite XAD-4 Resin Functionalized With N,N′-Bis(o and Their Determination by FAAS in Water Samples | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
