Publication:
Flow Injection Spectrofluorimetric Determination of Iron(III) in Water Using Salicylic Acid

dc.authorscopusid55984370700
dc.authorscopusid6701763136
dc.authorscopusid6603596907
dc.contributor.authorAsan, A.
dc.contributor.authorAndaç, M.
dc.contributor.authorIşıldak, I.
dc.date.accessioned2020-06-21T14:47:28Z
dc.date.available2020-06-21T14:47:28Z
dc.date.issued2010
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Asan] Adem, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Işıldak] İbrahim, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA simple and fast flow injection fluorescence quenching method for the determination of iron in water has been developed. Fluorimetric determination is based on the measurement of the quenching effect of iron on salicylic acid fluorescence. An emission peak of salicylic acid in aqueous solution occurs at 409 nm with excitation at 299 nm. The carrier solution used was 2 × 10-6 mol L-1 salicylic acid in 0.1 mol L-1 NH<inf>4</inf>+/NH<inf>3</inf> buffer solution at pH 8.5. Linear calibration was obtained for 5-100 μg L-1 iron(III) and the relative standard deviation was 1.25 % (n = 5) for a 20 μL injection volume iron(III). The limit of detection was 0.3 μg L-1 and the sampling rate was 60 h-1. The effect of interferences from various metals and anions commonly present in water was also studied. The method was successfully applied to the determination of low levels of iron in real samples (river, sea, and spring waters). © 2010 Institute of Chemistry, Slovak Academy of Sciences.en_US
dc.identifier.doi10.2478/s11696-010-0025-7
dc.identifier.endpage428en_US
dc.identifier.issn0366-6352
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-77952290718
dc.identifier.scopusqualityQ3
dc.identifier.startpage424en_US
dc.identifier.urihttps://doi.org/10.2478/s11696-010-0025-7
dc.identifier.volume64en_US
dc.identifier.wosWOS:000277369000003
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherVersitaen_US
dc.relation.ispartofChemical Papersen_US
dc.relation.journalChemical Papersen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFlow Injection Analysisen_US
dc.subjectFluorescence Quenchingen_US
dc.subjectIron(III)en_US
dc.subjectSalicylic Aciden_US
dc.titleFlow Injection Spectrofluorimetric Determination of Iron(III) in Water Using Salicylic Aciden_US
dc.typeArticleen_US
dspace.entity.typePublication

Files