Publication: Novel Approaches for Determining 30 MeV Proton Beam Energy and Dosimetric Parameters Using Stopping Power
| dc.authorscopusid | 57202847340 | |
| dc.authorscopusid | 8211625000 | |
| dc.authorscopusid | 56020089000 | |
| dc.authorscopusid | 55598954200 | |
| dc.authorscopusid | 57210339426 | |
| dc.authorscopusid | 15843124700 | |
| dc.authorwosid | Mutuk, Tugba/Aam-9056-2020 | |
| dc.authorwosid | Demirköz, Bilge/C-8179-2014 | |
| dc.authorwosid | Gürbüz, Mevlüt/Aag-4882-2019 | |
| dc.authorwosid | Yuksel, Zeynep/Aai-9285-2021 | |
| dc.authorwosid | Tufan, Mustafa/Abi-4079-2020 | |
| dc.authorwosid | Bilmez, Bayram/Aaa-5054-2022 | |
| dc.contributor.author | Yuksel, Zeynep | |
| dc.contributor.author | Tufan, M. Cagatay | |
| dc.contributor.author | Mutuk, Tugba | |
| dc.contributor.author | Gurbuz, Mevlut | |
| dc.contributor.author | Bilmez, Bayram | |
| dc.contributor.author | Demirkoz, M. Bilge | |
| dc.date.accessioned | 2025-12-11T00:48:55Z | |
| dc.date.issued | 2025 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Yuksel, Zeynep] Ondokuz Mayis Univ, Vocat Sch Hlth Serv, Med Serv & Tech Dept, TR-55139 Samsun, Turkiye; [Tufan, M. Cagatay] Ondokuz Mayis Univ, Grad Sch, Dept Radiol Sci, TR-55139 Samsun, Turkiye; [Mutuk, Tugba] Ondokuz Mayis Univ, Dept Met & Mat Engn, TR-55139 Samsun, Turkiye; [Gurbuz, Mevlut] Ondokuz Mayis Univ, Fac Engn, Dept Mech Engn, TR-55139 Samsun, Turkiye; [Bilmez, Bayram] Ondokuz Mayis Univ, Fac Sci, Dept Phys, TR-55139 Samsun, Turkiye; [Demirkoz, M. Bilge] Middle East Tech Univ METU, Fac Sci, Phys Dept, Ankara, Turkiye | en_US |
| dc.description.abstract | In this study, a different semiempirical method has been developed to determine the beam energy, which is crucial point in experimental studies. For this purpose, the Bragg curve was determined both experimentally using targets of different thicknesses and theoretically from stopping power values. By comparing Bragg curves, the beam energy can be estimated. This newly developed technique is easy to apply, and no additional apparatus is needed. In addition to determining the beam energy, dose values have been also determined with our stopping power values and MC calculation code. From these values, simple formulization has been obtained for percentage depth dose (PDD) values, which is also crucial for planning the radiation exposure. | en_US |
| dc.description.woscitationindex | Science Citation Index Expanded | |
| dc.identifier.doi | 10.1140/epjp/s13360-025-06888-8 | |
| dc.identifier.issn | 2190-5444 | |
| dc.identifier.issue | 10 | en_US |
| dc.identifier.scopus | 2-s2.0-105018178378 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.uri | https://doi.org/10.1140/epjp/s13360-025-06888-8 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/39492 | |
| dc.identifier.volume | 140 | en_US |
| dc.identifier.wos | WOS:001587509700002 | |
| dc.identifier.wosquality | Q2 | |
| dc.language.iso | en | en_US |
| dc.publisher | Springer Heidelberg | en_US |
| dc.relation.ispartof | European Physical Journal Plus | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.title | Novel Approaches for Determining 30 MeV Proton Beam Energy and Dosimetric Parameters Using Stopping Power | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |