Publication:
Novel Approaches for Determining 30 MeV Proton Beam Energy and Dosimetric Parameters Using Stopping Power

dc.authorscopusid57202847340
dc.authorscopusid8211625000
dc.authorscopusid56020089000
dc.authorscopusid55598954200
dc.authorscopusid57210339426
dc.authorscopusid15843124700
dc.authorwosidMutuk, Tugba/Aam-9056-2020
dc.authorwosidDemirköz, Bilge/C-8179-2014
dc.authorwosidGürbüz, Mevlüt/Aag-4882-2019
dc.authorwosidYuksel, Zeynep/Aai-9285-2021
dc.authorwosidTufan, Mustafa/Abi-4079-2020
dc.authorwosidBilmez, Bayram/Aaa-5054-2022
dc.contributor.authorYuksel, Zeynep
dc.contributor.authorTufan, M. Cagatay
dc.contributor.authorMutuk, Tugba
dc.contributor.authorGurbuz, Mevlut
dc.contributor.authorBilmez, Bayram
dc.contributor.authorDemirkoz, M. Bilge
dc.date.accessioned2025-12-11T00:48:55Z
dc.date.issued2025
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Yuksel, Zeynep] Ondokuz Mayis Univ, Vocat Sch Hlth Serv, Med Serv & Tech Dept, TR-55139 Samsun, Turkiye; [Tufan, M. Cagatay] Ondokuz Mayis Univ, Grad Sch, Dept Radiol Sci, TR-55139 Samsun, Turkiye; [Mutuk, Tugba] Ondokuz Mayis Univ, Dept Met & Mat Engn, TR-55139 Samsun, Turkiye; [Gurbuz, Mevlut] Ondokuz Mayis Univ, Fac Engn, Dept Mech Engn, TR-55139 Samsun, Turkiye; [Bilmez, Bayram] Ondokuz Mayis Univ, Fac Sci, Dept Phys, TR-55139 Samsun, Turkiye; [Demirkoz, M. Bilge] Middle East Tech Univ METU, Fac Sci, Phys Dept, Ankara, Turkiyeen_US
dc.description.abstractIn this study, a different semiempirical method has been developed to determine the beam energy, which is crucial point in experimental studies. For this purpose, the Bragg curve was determined both experimentally using targets of different thicknesses and theoretically from stopping power values. By comparing Bragg curves, the beam energy can be estimated. This newly developed technique is easy to apply, and no additional apparatus is needed. In addition to determining the beam energy, dose values have been also determined with our stopping power values and MC calculation code. From these values, simple formulization has been obtained for percentage depth dose (PDD) values, which is also crucial for planning the radiation exposure.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1140/epjp/s13360-025-06888-8
dc.identifier.issn2190-5444
dc.identifier.issue10en_US
dc.identifier.scopus2-s2.0-105018178378
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1140/epjp/s13360-025-06888-8
dc.identifier.urihttps://hdl.handle.net/20.500.12712/39492
dc.identifier.volume140en_US
dc.identifier.wosWOS:001587509700002
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherSpringer Heidelbergen_US
dc.relation.ispartofEuropean Physical Journal Plusen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleNovel Approaches for Determining 30 MeV Proton Beam Energy and Dosimetric Parameters Using Stopping Poweren_US
dc.typeArticleen_US
dspace.entity.typePublication

Files