Publication:
Comparison of LMA Ctrach and Video Laryngoscope in Endotracheal Intubation

dc.authorscopusid57223796000
dc.authorscopusid26028752200
dc.authorscopusid22942100300
dc.authorscopusid36707874100
dc.authorscopusid13103796700
dc.authorscopusid23397837900
dc.authorscopusid23397837900
dc.authorwosidDilek, Ahmet/Aav-7176-2021
dc.contributor.authorGumus, Nevzat
dc.contributor.authorDilek, Ahmet
dc.contributor.authorUlger, Fatma
dc.contributor.authorKoksal, Ersin
dc.contributor.authorCetinoglu, Erhan Cetin
dc.contributor.authorOzkan, Fatih
dc.contributor.authorGuldogus, Fuat
dc.contributor.authorIDDilek, Ahmet/0000-0001-7111-2438
dc.date.accessioned2020-06-21T09:37:39Z
dc.date.available2020-06-21T09:37:39Z
dc.date.issued2014
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Gumus, Nevzat; Dilek, Ahmet; Ulger, Fatma; Koksal, Ersin; Cetinoglu, Erhan Cetin; Ozkan, Fatih; Guldogus, Fuat] Ondokuz Mayis Univ, Tip Fak, Anesteziyol Reanimasyon Anabilim Dali, Samsun, Turkeyen_US
dc.descriptionDilek, Ahmet/0000-0001-7111-2438en_US
dc.description.abstractObjective: In this study, our objective was to compare the Cormack and Lehane (C-L) sight scores of direct laryngoscopy in endotracheal intubation with the endoscopic sight scores of the LMA CTrach and video laryngoscope. We also compared the success of endoscopy with the LMA CTrach and video laryngoscopy, intubation time, and its effects on haemodynamic and stress responses. Methods: The study included 100 patients, with American Society of Anesthesiologists (ASA) scores I-III and aged 18-65, who will undergo elective surgery. Patients were randomly divided into two groups: Group C and Group V. The patients in both groups underwent direct laryngoscopy with a Macintosh laryngoscope, and their C-L scores were recorded. In Group C, the patients were intubated with the LMA CTrach, and in Group V, the patients were intubated with a video laryngoscope. Patients' haemodynamic parameters, oxygen saturation, end-tidal carbondioxide, and endoscopic sight scores were recorded. Results: The demographic characteristics and the ASA classifications of the groups were similar. When endoscopic sight scores were compared with C-L, better sight was obtained in the LMA CTrach group; no significant difference was detected in Group V. Regarding the success of the intubation, no significant difference was detected between groups. However, when intubation times were compared, there was a significant difference between groups. The intubation time was longer in Group C. There was no difference between groups in terms of the percentage changes of haemodynamic parameters, oxygen saturation, and end-tidal carbondioxide values of the patients. Conclusion: In this study, when endoscopic sight scores were compared, better visualization was obtained in the LMA CTrach group. Therefore, in cases where intubation is difficult to apply in patients, the LMA CTrach can be an alternative application.en_US
dc.description.sponsorshipOndokuz Mayis University Scientific Research Foundationen_US
dc.description.sponsorshipThis study was supported by the Ondokuz Mayis University Scientific Research Foundation.en_US
dc.description.woscitationindexEmerging Sources Citation Index
dc.identifier.doi10.5152/TJAR.2014.58815
dc.identifier.endpage256en_US
dc.identifier.issn2149-0937
dc.identifier.issn2149-276X
dc.identifier.issue5en_US
dc.identifier.pmid27366431
dc.identifier.scopus2-s2.0-84907060154
dc.identifier.startpage251en_US
dc.identifier.urihttps://doi.org/10.5152/TJAR.2014.58815
dc.identifier.volume42en_US
dc.identifier.wosWOS:000218636000004
dc.language.isotren_US
dc.publisherAvesen_US
dc.relation.journalTurk Anesteziyoloji ve Reanimasyon Dernegi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectLMA Ctrachen_US
dc.subjectVideo Laryngoscopeen_US
dc.subjectEndoscopic Sight Scoresen_US
dc.subjectEndotracheal Intubationen_US
dc.titleComparison of LMA Ctrach and Video Laryngoscope in Endotracheal Intubationen_US
dc.title.alternativeEndotrakeal Entübasyonda LMA CTrach ve Video Laringoskop Yöntemlerinin Karşılaştırılmasıen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files