Publication:
Clinicopathological Variables That Correlate With Sestamibi Positivity in Uniglandular Parathyroid Disease: A Retrospective Analysis of 378 Parathyroid Adenomas

dc.authorscopusid57204843448
dc.authorscopusid13407057000
dc.authorscopusid22934849400
dc.authorscopusid22934583100
dc.authorscopusid59158511100
dc.authorscopusid57220084570
dc.authorscopusid56210371100
dc.authorwosidKefeli, Mehmet/Juu-8095-2023
dc.authorwosidMert, Meral/Kxr-1439-2024
dc.authorwosidBayçelebi, Deniz/Abc-8355-2021
dc.authorwosidPolat, Cafer/Hji-0593-2023
dc.authorwosidDurmuş, Elif Tutku/Ivv-0483-2023
dc.contributor.authorDurmus, Elif Tutku
dc.contributor.authorAtmaca, Aysegul
dc.contributor.authorKefeli, Mehmet
dc.contributor.authorMete, Ozgur
dc.contributor.authorTosun, Fevziye Canbaz
dc.contributor.authorBaycelebi, Deniz
dc.contributor.authorColak, Ramis
dc.contributor.authorIDMete, Ozgur/0000-0003-0469-2801
dc.date.accessioned2025-12-11T01:05:44Z
dc.date.issued2022
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Durmus, Elif Tutku; Atmaca, Aysegul; Colak, Ramis] Ondokuz Mayis Univ, Dept Endocrinol & Metab, Sch Med, Samsun, Turkey; [Kefeli, Mehmet; Baycelebi, Deniz] Ondokuz Mayis Univ, Dept Pathol, Sch Med, Samsun, Turkey; [Mete, Ozgur] Univ Hlth Network, Dept Pathol, Toronto, ON, Canada; [Mete, Ozgur] Univ Toronto, Dept Lab Med & Pathobiol, Toronto, ON, Canada; [Tosun, Fevziye Canbaz] Ondokuz Mayis Univ, Dept Nucl Med, Sch Med, Samsun, Turkey; [Polat, Cafer] Ondokuz Mayis Univ, Dept Gen Surg, Sch Med, Samsun, Turkeyen_US
dc.descriptionMete, Ozgur/0000-0003-0469-2801;en_US
dc.description.abstractPurpose Technetium-99 m sestamibi parathyroid scintigraphy (MIBI scan) has been used to localize abnormal glands in patients with primary hyperparathyroidism to guide parathyroidectomy. This series aimed to identify the biochemical and histopathological correlates of MIBI scan findings in patients with parathyroid adenoma. Methods A total of 378 patients with histologically and biochemically proven parathyroid adenoma were included. The results of MIBI scan, histopathological (gland volume and weight, oxyphil cell ratio), biochemical (blood and 24 h urine calcium, creatinine, glomerular filtration rate, parathormone, alkaline phosphate, and vitamin D3) variables were recorded. A positive uptake on the MIBI scan referred to a localized adenoma. Among histological variables, a cutoff of 30% was applied to define parathyroid adenomas with low (<= 30%) and high (> 30%) oxyphil cell content. Statistical analyses were performed to assess the relationship among variables. Results MIBI scan localized the adenoma in 306 patients. Parathyroid gland volume and weight, and oxyphil ratio were significantly higher in the MIBI scan-positive group. Among the biochemical variables, only PTH was found to be significantly increased in the MIBI scan-positive group. Binary logistic regression models identified statistically significant cutoffs for the gland volume (1700 mm(3)), gland weight (1.3 g) and PTH levels (170 pg/mL) that can be used to predict the MIBI scan positivity. Conclusion In addition to PTH levels, this series underscored the impact of cellular composition along with the parathyroid gland volume and weight, both of which correlate with sestamibi positivity in patients with benign uniglandular parathyroid disease.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1007/s12149-021-01681-w
dc.identifier.endpage42en_US
dc.identifier.issn0914-7187
dc.identifier.issn1864-6433
dc.identifier.issue1en_US
dc.identifier.pmid34580842
dc.identifier.scopus2-s2.0-85115788087
dc.identifier.scopusqualityQ2
dc.identifier.startpage33en_US
dc.identifier.urihttps://doi.org/10.1007/s12149-021-01681-w
dc.identifier.urihttps://hdl.handle.net/20.500.12712/41310
dc.identifier.volume36en_US
dc.identifier.wosWOS:000701007900001
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofAnnals of Nuclear Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectParathyroid Adenomaen_US
dc.subjectDiagnosisen_US
dc.subjectOxyphilsen_US
dc.subjectScintigraphyen_US
dc.subjectSestamibien_US
dc.subjectUniglandular Parathyroid Diseaseen_US
dc.titleClinicopathological Variables That Correlate With Sestamibi Positivity in Uniglandular Parathyroid Disease: A Retrospective Analysis of 378 Parathyroid Adenomasen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files