Repository logo

Publication:
Percutaneous Transluminal Balloon Pulmonary Valvuloplasty - Immediate and Medium Term Results

dc.authorwosidCeliker, Alpay/O-6067-2019
dc.contributor.authorOzme, S.
dc.contributor.authorCeliker, A.
dc.contributor.authorOzkutlu, S.
dc.contributor.authorOzer, S.
dc.contributor.authorBaysal, K.
dc.date.accessioned2025-12-11T00:37:18Z
dc.date.issued1990
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-tempHACETTEPE UNIV, INST CHILD HLTH, ANKARA, TURKEY; ONDOKUZMAYIS UNIV, FAC MED, SAMSUN, TURKEYen_US
dc.description.abstractTen patients with pulmonary stenosis, (six males and four females) whose ages ranged between five and ten years (mean age 7 years) underwent cardiac catheterization and balloon valvuloplasty. Right ventricular systolic pressure before valvuloplasty ranged from 90 to 200 mm Hg (mean 133.5 +/- 33.3 mm Hg). It fell to 50-90 mm Hg (mean 64.5 +/- 13.8 mm Hg) immediately after the procedure. The peak systolic gradient across the pulmonary valve before valvuloplasty ranged from 70 to 180 mm Hg (mean 114.5 +/- 35.4 mm Hg) and decreased significantly to 30-70 mm Hg (mean 43.0 +/- 13.8 mm Hg) immediately after dilation. Doppler echo studies confirmed these results. At repeat cardiac catheterization in three patients, five to 15 months after valvuloplasty, restenosis was noted in one patient while there was no change in the others. All patients had been followed up by Doppler echocardiography. Patients with isolated valvular pulmonary stenosis can be adequately and safely treated with balloon valvuloplasty which results in excellent immediate and medium-term results.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.endpage31en_US
dc.identifier.issn0041-4301
dc.identifier.issue1en_US
dc.identifier.pmid2288015
dc.identifier.scopusqualityQ3
dc.identifier.startpage25en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12712/37945
dc.identifier.volume32en_US
dc.identifier.wosWOS:A1990ER99000004
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherTurkish J. Pediatricsen_US
dc.relation.ispartofTurkish Journal of Pediatricsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBalloon Valvuloplastyen_US
dc.subjectPulmonary Valvular Stenosisen_US
dc.subjectChildrenen_US
dc.subjectImmediate and Medium-Term Resultsen_US
dc.titlePercutaneous Transluminal Balloon Pulmonary Valvuloplasty - Immediate and Medium Term Resultsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files