Publication:
Comparison of Anterior Segment Parameters Obtained by Dual-Scheimpflug Analyzer Before and After Cycloplegia in Children

dc.authorscopusid16245928800
dc.authorscopusid55125592200
dc.authorscopusid57190435791
dc.authorscopusid57190436970
dc.contributor.authorNi̇yaz, L.
dc.contributor.authorCan, E.
dc.contributor.authorSeymen, Z.
dc.contributor.authorEraydin, B.
dc.date.accessioned2020-06-21T13:32:39Z
dc.date.available2020-06-21T13:32:39Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Ni̇yaz] Leyla, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Can] Ertugrul, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Seymen] Zeynep, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Eraydin] Bilge, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractPurpose: To assess the changes of anterior segment parameters with cycloplegia. Methods: A cross-sectional study of healthy pediatric patients was performed. Anterior segment parameters were obtained by the Galilei Dual-Scheimpflug analyzer (Ziemer Group, Port, Switzerland) before and 40 minutes after the instillation of cyclopentolate. The effect of gender was evaluated. Results: There were 43 boys and 50 girls with a mean age of 7.76 ± 2.7 years. There was a significant increase in anterior chamber depth, anterior chamber volume, and pupil diameter after the cycloplegia (P < .05). The anterior chamber angle increased after cycloplegia in the nasal, temporal, and inferior quadrants (P < .05), but not in the superior quadrant (P > .05). The mean values of anterior segment parameters were similar in both genders. Conclusions: The values of anterior chamber depth, anterior chamber volume, anterior chamber angle, and pupil diameter measured with the Galilei Dual-Scheimpflug analyzer increased significantly after cycloplegia. Gender did not have an effect on anterior segment parameters. © SLACK Incorporated.en_US
dc.identifier.doi10.3928/01913913-20160427-02
dc.identifier.endpage237en_US
dc.identifier.issn0191-3913
dc.identifier.issn1938-2405
dc.identifier.issue4en_US
dc.identifier.pmid27182749
dc.identifier.scopus2-s2.0-84980023208
dc.identifier.scopusqualityQ3
dc.identifier.startpage234en_US
dc.identifier.urihttps://doi.org/10.3928/01913913-20160427-02
dc.identifier.volume53en_US
dc.identifier.wosWOS:000393046200009
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherSlack Incorporated customerservice@slackinc.comen_US
dc.relation.ispartofJournal of Pediatric Ophthalmology & Strabismusen_US
dc.relation.journalJournal of Pediatric Ophthalmology & Strabismusen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleComparison of Anterior Segment Parameters Obtained by Dual-Scheimpflug Analyzer Before and After Cycloplegia in Childrenen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files