Publication: Electrode Fixation with Bone Cement or Stimloc® in Deep Brain Stimulation Surgery: A Comparative Study
| dc.authorscopusid | 57703061000 | |
| dc.authorscopusid | 23994026500 | |
| dc.authorscopusid | 55695947500 | |
| dc.authorscopusid | 56060156200 | |
| dc.authorscopusid | 6603019677 | |
| dc.authorwosid | Yildiz, Mustafa Onur/Gry-0328-2022 | |
| dc.authorwosid | Ozturk, Sait/Q-1953-2016 | |
| dc.contributor.author | Taskin, Onder | |
| dc.contributor.author | Kocabicak, Ersoy | |
| dc.contributor.author | Ozturk, Sait | |
| dc.contributor.author | Yildiz, Onur | |
| dc.contributor.author | Temel, Yasin | |
| dc.contributor.authorID | Ozturk, Sait/0000-0002-7655-0127 | |
| dc.contributor.authorID | Kocabicak, Ersoy/0000-0003-3445-1734 | |
| dc.date.accessioned | 2025-12-11T01:18:55Z | |
| dc.date.issued | 2022 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Taskin, Onder] Minist Hlth, Carsamba Govt Hosp, Neurosurg Clin, Samsun, Turkey; [Kocabicak, Ersoy] Ondokuz Mayis Univ, Dept Neurosurg, Sch Med, Samsun, Turkey; [Kocabicak, Ersoy] Ondokuz Mayis Univ, Neuromodulat Ctr, Sch Med, Samsun, Turkey; [Ozturk, Sait] Altinbas Univ, Dept Neurosurg, Med Pk Bahcelievler Hosp, Istanbul, Turkey; [Yildiz, Onur] Ondokuz Mayis Univ, Sch Med, Dept Neurol, Samsun, Turkey; [Temel, Yasin] Maastricht Univ, Med Ctr, Dept Neurosurg, Maastricht, Netherlands; [Temel, Yasin] Maastricht Univ, Med Ctr, Dept Neurosci, Maastricht, Netherlands | en_US |
| dc.description | Ozturk, Sait/0000-0002-7655-0127; Kocabicak, Ersoy/0000-0003-3445-1734 | en_US |
| dc.description.abstract | AIM: To examine the postoperative outcomes of electrode fixation using bone cement and Stimloc?? in patients with Parkinson???s MATERIAL and METHODS: Between 2016 and 2018, permanent electrode fixation was performed in 30 patients with PD, of which 15 received bone cement and the remaining 15 received Stimloc??. Data regarding preoperative Unified Parkinson???s Disease Rating Scale (UPDRS) III scores, levodopa equivalent daily dose (LEDD) values, surgery duration, and the fixation technique used were recorded. Brain computed tomography was performed for early postoperative evaluation of pneumocephalus and possible hematoma as well as for the determination of migration 1 year postoperatively. UPDRS III scores and LEDD values were re-evaluated 1 year postoperatively; surgery duration, clinical effectiveness, and complication rates were compared between the two fixation techniques. RESULTS: A statistically significant difference in application time was observed between the two techniques (bone cement: 21 min, Stimloc??: 6 min). After 1 year from surgery, 0.92- and 0.88-mm migrations were observed in the bone cement and Stimloc?? groups, respectively. A significant correlation between migration and the pneumocephalus volume was observed in both groups. No differences were observed between the groups regarding infection, migration, pneumocephalus volume, wound erosion, and CONCLUSION: Stimloc?? is preferred over bone cement for electrode fixation in DBS surgeries as it is associated with shorter application duration; this increases patient comfort and tolerance during awake surgery. Clinical efficacy and complication rates associated with both techniques are similar. | en_US |
| dc.description.sponsorship | Turkish Neurosurgical Society | en_US |
| dc.description.sponsorship | Preparation for publication of this article is partly supported by Turkish Neurosurgical Society. | en_US |
| dc.description.woscitationindex | Science Citation Index Expanded | |
| dc.identifier.doi | 10.5137/1019-5149.JTN.35635-21.2 | |
| dc.identifier.endpage | 458 | en_US |
| dc.identifier.issn | 1019-5149 | |
| dc.identifier.issue | 3 | en_US |
| dc.identifier.pmid | 35147967 | |
| dc.identifier.scopus | 2-s2.0-85130483011 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 449 | en_US |
| dc.identifier.uri | https://doi.org/10.5137/1019-5149.JTN.35635-21.2 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/42794 | |
| dc.identifier.volume | 32 | en_US |
| dc.identifier.wos | WOS:000804648400015 | |
| dc.identifier.wosquality | Q3 | |
| dc.language.iso | en | en_US |
| dc.publisher | Turkish Neurosurgical Society | en_US |
| dc.relation.ispartof | Turkish Neurosurgery | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Deep Brain Stimulation | en_US |
| dc.subject | Parkinson's Disease | en_US |
| dc.subject | Subthalamic Nucleus | en_US |
| dc.subject | Stimloc | en_US |
| dc.subject | Bone Cement | en_US |
| dc.title | Electrode Fixation with Bone Cement or Stimloc® in Deep Brain Stimulation Surgery: A Comparative Study | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
