Publication:
İmplantüstü Sabit Bölümlü Protezlerde Kullanılan Seramik İmplant Dayanaklarının Sonlu Elemanlar Yöntemi ile İncelenmesi

dc.contributor.advisorSaraç, Y.doç.dr. Duygu
dc.contributor.authorYüzbaşıoğlu, Hüseyin Emir
dc.date.accessioned2020-07-22T09:08:14Z
dc.date.available2020-07-22T09:08:14Z
dc.date.issued2006
dc.departmentOMÜ, Sosyal Bilimler Enstitüsü, Protetik Diş Tedavisi Anabilim Dalıen_US
dc.departmentSağlık Bilimleri Enstitüsü / Protetik Diş Tedavisi Ana Bilim Dalı
dc.descriptionTez (doktora) -- Ondokuz Mayıs Üniversitesi, 2006en_US
dc.descriptionLibra Kayıt No: 17086en_US
dc.description.abstractÖZETMPLANTÜSTÜ SAB T BÖLÜMLÜ PROTEZLERDE KULLANILAN SERAM KMPLANT DAYANAKLARININ SONLU ELEMANLAR YÖNTEM LENCELENMESHüseyin Emir YÜZBAŞIOĞLU, Doktora TeziOndokuz Mayıs Üniversitesi, Samsun, Temmuz 2006Diş hekimliğinde tam seramik sistemlerin kullanımının ve implant tedavisininyaygınlaşması sonucunda seramik implant dayanaklarına olan ilgi artmıştır. Bu çalışmada, üçfarklı seramik ve bir titanyum implant dayanağı kullanılarak hazırlanan üç ve dört üyeli sabitbölümlü protezlerde, fonksiyonel kuvvetler altında mekanik ve fiziksel özelliklerindeoluşabilecek değişiklikler ve çevre dokulardaki stres dağılımlarının üç boyutlu sonluelemanlar yöntemi ile incelenmesi amaçlandı.Üç farklı seramik ve bir titanyum implant dayanağı ile hazırlanmış üç ve dört üyelisabit bölümlü protez modelleri üzerinde vertikal ve oblik kuvvetlerin oluşturduğu stresler,MSC. Patran 2005 analiz programı kullanılarak değerlendirildi. Vertikal ve oblik kuvvetleruygulandığında, tüm implant dayanaklarında, sabit bölümlü protezlerde, implant parçalarındave destekleyici dokularda oluşan stresler, Von Mises, maksimum principle ve minimumprinciple stres değerleri kullanılarak karşılaştırıldı.Elde edilen sonuçlarda, seramik implant dayanaklarının kullanıldığı modellerde, heriki yükleme koşulunda titanyum dayanağa benzer stres alanları görüldü. Seramik implantdayanaklarında elde edilen stres değerleri yoğun sinterlenmiş alüminyum oksit esaslı implantdayanağı >zirkonyum oksit ile güçlendirilmiş infiltrasyon seramiği esaslı implant dayanağı >zirkonyum oksit esaslı implant dayanağı şeklinde sıralandı. Sabit bölümlü protez alt yapıporseleninde seramik implant dayanağı kullanılan modellerde titanyum implant dayanağınagöre daha yüksek stres değerleri görülürken, üst yapı porseleninde herhangi bir farkbulunmadı. Dört üyeli implantüstü sabit bölümlü protez modellerinde, üç üyeli modellere göredaha yüksek stres değerleri elde edildi.Bütün bu veriler doğrultusunda seramik implant dayanaklarının posterior bölgedetitanyum implant dayanaklarına alternatif olarak önerilebileceği ve bu çalışmada daha düşükstres değerleri gösteren zirkonyum oksit esaslı implant dayanağının, diğer seramikdayanaklara göre klinik olarak kullanımının daha güvenli olabileceği düşünülmektedir.
dc.description.abstractABSTRACTTHE INVESTIGATION OF THE CERAMIC IMPLANT ABUTMENTS USED INIMPLANT SUPPORTED FIXED DENTURES BY FINITE ELEMENT METHODHüseyin Emir YÜZBAŞIOĞLU, Ph.D. ThesisOndokuz Mayıs University, Samsun, July 2006As a result of the widespread usage of all-ceramic systems and implant therapy, theinterest concerning ceramic implant abutments are increasing. In this study, the evaluation ofthe changes of mechanical and physical properties of three different ceramic and titaniumimplant abutments, which were used in three and four unit fixed partial dentures, underfunctional forces by three dimensional finite element method was aimed.The stresses which were generated under vertical and oblique forces on three and fourunit fixed partial dentures were evaluated by using MSC Patran 2005 analysis program. Thestresses which occurred under vertical and oblique forces at the implant abutments, implantcomponents, fixed partial dentures and supporting tissues were evaluated comparatively byusing Von Mises, maximum principle and minimum principle stress values in mega Pascalunit.In ceramic abutment models similar stress regions were seen for both loadingconditions, such as with titanium abutment models. The stresses of ceramic abutments werearranged in descending order: densely sintered aluminium oxide implant abutment >zirconium oxide toughened infiltration ceramic based implant abutment > zirconium oxidebased implant abutment. The stress values of the ceramic framework of fixed partial dentureswere higher in ceramic abutment models than in titanium abutment models. No differenceswere found in the stress values of veneering porcelain. Higher stress values were observed forthe four-unit fixed partial denture models than for the three-unit models.As a result of this study, it can be stated that ceramic implant abutments can serve asan alternative for titanium abutments in the posterior region. Zirconium oxide based implantabutments which exhibited lower stress values in this study, should be preferred clinically.en_US
dc.formatXI, 149 y. : şekil, tablo ; 30 sm.en_US
dc.identifier.endpage161
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=XohQ0H2mJnBfxLPsY8dG484e4Kmvw7MaVXA5OvclOOhyMt1tjNLSaRZjHz3qLy52
dc.identifier.urihttp://libra.omu.edu.tr/tezler/17086.pdf
dc.identifier.yoktezid192503
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Sosyal Bilimler Enstitüsüen_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDentistryen_US
dc.subjectDiş Hekimliği
dc.subject.otherTEZ DOK Y95i 2006en_US
dc.titleİmplantüstü Sabit Bölümlü Protezlerde Kullanılan Seramik İmplant Dayanaklarının Sonlu Elemanlar Yöntemi ile İncelenmesi
dc.titleThe Investigation of the Ceramic Implant Abutments Used in Implant Supported Fixed Dentures by Finite Element Methoden_US
dc.typeDoctoral Thesisen_US
dspace.entity.typePublication

Files