Publication:
Flow-Injection Spectrophotometric Determination of Nanogram Levels of Iron(III) With N,N-Dimethylformamide

dc.authorscopusid55984370700
dc.authorscopusid6701763136
dc.authorscopusid6603596907
dc.contributor.authorAsan, A.
dc.contributor.authorAndaç, M.
dc.contributor.authorIşıldak, I.
dc.date.accessioned2020-06-21T15:44:08Z
dc.date.available2020-06-21T15:44:08Z
dc.date.issued2003
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Asan] Adem, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Işıldak] İbrahim, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA simple and fast flow-injection spectrophotometric method has been described for the determination of iron(III). The method is based on the measurement of absorbance intensity of the complex that is formed between iron(III) and N,N-dimethylformamide (DMF) at 310 nm. The carrier stream was just a mixture of water and DMF at ratio 5% (v/v). The method is highly selective; most of the 30 metal ions and anions tested did not effect on the determination of iron(III) even when present up to 1000-fold excess over iron(III). The calibration graph for iron(III) obtained under optimized conditions were linear in the range 5 - 90 ng ml-1 with a detection limit of 0.1 ng ml-1 for a 20 μl injection volume. The reproducibility was satisfactory, with a relative standard deviation of 2.4% (n = 5) in the range of 5 - 90 ng ml-1 of iron(III). The sampling rate was over 60 h-1. The developed method was succesfully applied to the determination of total iron in river water, seawater, hot spring water and iron alloy samples. The accuracy of the method was evaluated using the standard addition method and checked by the certified reference metal alloy samples.en_US
dc.identifier.doi10.2116/analsci.19.1033
dc.identifier.endpage1036en_US
dc.identifier.issn0910-6340
dc.identifier.issn1348-2246
dc.identifier.issue7en_US
dc.identifier.pmid12880088
dc.identifier.scopus2-s2.0-0042816282
dc.identifier.scopusqualityQ3
dc.identifier.startpage1033en_US
dc.identifier.urihttps://doi.org/10.2116/analsci.19.1033
dc.identifier.volume19en_US
dc.identifier.wosWOS:000184211300011
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherJapan Society for Analytical Chemistryen_US
dc.relation.ispartofAnalytical Sciencesen_US
dc.relation.journalAnalytical Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleFlow-Injection Spectrophotometric Determination of Nanogram Levels of Iron(III) With N,N-Dimethylformamideen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files