Publication:
Rapid Determination of Trace Level Copper in Tea Infusion Samples by Solid Contact Ion Selective Electrode

dc.authorscopusid56110004000
dc.authorscopusid55013129200
dc.authorscopusid25921912000
dc.authorscopusid7004269359
dc.authorscopusid6701763136
dc.contributor.authorBirinci, A.
dc.contributor.authorEren, H.
dc.contributor.authorColdur, F.
dc.contributor.authorÇoşkun, E.
dc.contributor.authorAndaç, M.
dc.date.accessioned2020-06-21T13:32:52Z
dc.date.available2020-06-21T13:32:52Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Birinci] Aysenur, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Eren] Hilal, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Coldur] Fatih, Department of Chemistry, Erzincan Binali Yıldırım Üniversitesi, Erzincan, Turkey; [Çoşkun] Emine, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA new solid contact copper selective electrode with a poly (vinyl chloride) (PVC) membrane consisting of o-xylylenebis(N,N-diisobutyldithiocarbamate) as ionophore has been prepared. The main novelties of constructed ion selective electrode concept are the enhanced robustness, cheapness, and fastness due to the use of solid contacts. The electrode exhibits a rapid (< 10 seconds) and near-Nernstian response to Cu2+ activity from 10−1 to 10−6 mol/L at the pH range of 4.0–6.0. No serious interference from common ions was found. The electrode characterizes by high potential stability, reproducibility, and full repeatability. The electrode was used as an indicator electrode in potentiometric titration of Cu(II) ions with EDTA and for the direct assay of tea infusion samples by means of the calibration graph technique. The results compared favorably with those obtained by the atomic absorption spectroscopy (AAS). © 2016en_US
dc.identifier.doi10.1016/j.jfda.2016.02.012
dc.identifier.endpage492en_US
dc.identifier.issn1021-9498
dc.identifier.issn2224-6614
dc.identifier.issue3en_US
dc.identifier.pmid28911553
dc.identifier.scopus2-s2.0-84964260527
dc.identifier.scopusqualityQ2
dc.identifier.startpage485en_US
dc.identifier.urihttps://doi.org/10.1016/j.jfda.2016.02.012
dc.identifier.volume24en_US
dc.identifier.wosWOS:000387936400005
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherElsevier Taiwan LLC 96 Chung Shan North Road, Section 2 Taipeien_US
dc.relation.ispartofJournal of Food and Drug Analysisen_US
dc.relation.journalJournal of Food and Drug Analysisen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCopperen_US
dc.subjectPolyvinyl Chloride (PVC) Membraneen_US
dc.subjectPotentiometryen_US
dc.subjectSolid Contacten_US
dc.subjectTea Infusion Samplesen_US
dc.titleRapid Determination of Trace Level Copper in Tea Infusion Samples by Solid Contact Ion Selective Electrodeen_US