Publication:
P-Wave Dispersion and Atrial Electromechanical Delay in Patients With Preeclampsia

dc.authorscopusid36703943100
dc.authorscopusid55920255300
dc.authorscopusid56107735600
dc.authorscopusid56948135900
dc.authorscopusid6508154992
dc.authorscopusid15118921600
dc.contributor.authorInci, S.
dc.contributor.authorNar, G.
dc.contributor.authorAksan, G.
dc.contributor.authorSipahioʇlu, H.
dc.contributor.authorSoylu, K.
dc.contributor.authorDoǧan, A.
dc.date.accessioned2020-06-21T13:51:18Z
dc.date.available2020-06-21T13:51:18Z
dc.date.issued2015
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Inci] Sinan, Department of Cardiology, Aksaray State Hospital, Aksaray, Aksaray, Turkey; [Nar] Gökay, Department of Cardiology, Aksaray State Hospital, Aksaray, Aksaray, Turkey; [Aksan] Gökhan, Department of Cardiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Sipahioʇlu] Haydar, Department of Obstetrics, Aksaray State Hospital, Aksaray, Aksaray, Turkey; [Soylu] Korhan, Department of Cardiology, Ondokuz Mayis University, Medical School, Samsun, Turkey; [Doǧan] Ali, Department of Cardiology, Erciyes University, Faculty of Medicine, Kayseri, Turkeyen_US
dc.description.abstractObjectives: To investigate the duration of atrial electromechanical delay (EMD) and left atrial mechanical function in patients with preeclampsia. Materials and Methods: This study included 26 pregnant women with preeclampsia and 24 age-matched pregnant women without preeclampsia (control group). Atrial electromechanical coupling (PA) and intra-atrial and interatrial EMD were measured using tissue Doppler echocardiography. P-wave dispersion (PWD) was measured via 12-lead electrocardiography. All data were analyzed using SPSS v.15.0 for Windows (SPSS, Inc., Chicago, Ill., USA). Differences in continuous variables between groups were examined using a nonparametric Mann-Whitney U test. Correlation analysis was performed using Spearman's coefficient of correlation. Categorical values were compared using a χ2 test. Results: PA lateral and PA septal durations were significantly longer in the preeclampsia group than in the control group [74.6 ± 8.1 vs. 62.3 ± 5.3 ms (p < 0.001) and 59.7 ± 5.3 vs. 56.2 ± 4.9 ms (p = 0.005), respectively]. The duration of interatrial EMD and intra-atrial EMD in the preeclampsia group was significantly longer than in the control group [25.4 ± 4.6 vs. 13.2 ± 3.9 ms (p < 0.001) and 10.5 ± 1.9 vs. 7.1 ± 1.2 ms (p < 0.001), respectively]. PWD was significantly higher in patients with preeclampsia (43.1 ± 9.1 ms) than in the controls (37.6 ± 7.9 ms; p = 0.008). There was a significant correlation between PWD and interatrial EMD and intra-atrial EMD [r = 0.46 (p < 0.001) and r = 0.39 (p < 0.001), respectively]. Conclusion: The duration of atrial EMD and PWD was prolonged in patients with preeclampsia. © 2015 S. Karger AG, Basel.en_US
dc.identifier.doi10.1159/000435857
dc.identifier.endpage521en_US
dc.identifier.issn1011-7571
dc.identifier.issn1423-0151
dc.identifier.issue6en_US
dc.identifier.pmid26278001
dc.identifier.scopus2-s2.0-84946498322
dc.identifier.scopusqualityQ1
dc.identifier.startpage515en_US
dc.identifier.urihttps://doi.org/10.1159/000435857
dc.identifier.volume24en_US
dc.identifier.wosWOS:000364216200003
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherS. Karger AGen_US
dc.relation.ispartofMedical Principles and Practiceen_US
dc.relation.journalMedical Principles and Practiceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAtrial Electromechanical Delayen_US
dc.subjectInteratrial Conduction Timeen_US
dc.subjectIntra-Atrial Conduction Timeen_US
dc.subjectPreeclampsiaen_US
dc.subjectTissue Doppler Imagingen_US
dc.titleP-Wave Dispersion and Atrial Electromechanical Delay in Patients With Preeclampsiaen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files