Publication: Spectrophotometric Determination of Copper(II) at Low μg 1-1 Levels Using Cation-Exchange Microcolumn in Flow-Injection
| dc.authorscopusid | 6603596907 | |
| dc.authorscopusid | 55984370700 | |
| dc.authorscopusid | 6701763136 | |
| dc.contributor.author | Işıldak, I. | |
| dc.contributor.author | Asan, A. | |
| dc.contributor.author | Andaç, M. | |
| dc.date.accessioned | 2020-06-21T15:51:00Z | |
| dc.date.available | 2020-06-21T15:51:00Z | |
| dc.date.issued | 1999 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Işıldak] İbrahim, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Asan] Adem, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | A simple spectrophotometric flow-injection method is reported for the highly sensitive and fast determination of copper(II). The method is based on the formation of coloured Cu(II)-(4-methylpiperidinedithiocarbamate)<inf>2</inf> complex when the copper solutions are introduced into a tertiary reagent stream containing 4-methylpiperidinedithiocarbamate. The coloured complex is then selectively monitored at 435 nm. To increase interactions between copper(II) and colour forming reagent and preconcentrate of copper(II), a microcolumn containing strong cation exchange resins was placed between injection manifold and spectrophotometer. The system required no mixing chamber and allowed a sample throughput > 60 sample h-1. The calibration graph was linear in the range 5-100 μg 1-1. The detection limit was < 0.5 μg 1-1 for 20 μl injection volume of copper(II) ion solution. The developed method was applied to environmental, copper processing water, and ore samples. | en_US |
| dc.identifier.doi | 10.1016/S0039-9140(98)00241-0 | |
| dc.identifier.endpage | 224 | en_US |
| dc.identifier.issn | 0039-9140 | |
| dc.identifier.issn | 1873-3573 | |
| dc.identifier.issue | 1 | en_US |
| dc.identifier.pmid | 18967461 | |
| dc.identifier.scopus | 2-s2.0-0345320395 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 219 | en_US |
| dc.identifier.uri | https://doi.org/10.1016/S0039-9140(98)00241-0 | |
| dc.identifier.volume | 48 | en_US |
| dc.identifier.wos | WOS:000077958700025 | |
| dc.identifier.wosquality | Q1 | |
| dc.language.iso | en | en_US |
| dc.publisher | Elsevier | en_US |
| dc.relation.ispartof | Talanta | en_US |
| dc.relation.journal | Talanta | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | 4-Methylpiperidine-Dithiocarbamate | en_US |
| dc.subject | Copper(II) Determination | en_US |
| dc.subject | Flow-Injection Photometric Method | en_US |
| dc.subject | Microcolumn | en_US |
| dc.title | Spectrophotometric Determination of Copper(II) at Low μg 1-1 Levels Using Cation-Exchange Microcolumn in Flow-Injection | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
