Publication:
Spectrophotometric Determination of Copper(II) at Low μg 1-1 Levels Using Cation-Exchange Microcolumn in Flow-Injection

dc.authorscopusid6603596907
dc.authorscopusid55984370700
dc.authorscopusid6701763136
dc.contributor.authorIşıldak, I.
dc.contributor.authorAsan, A.
dc.contributor.authorAndaç, M.
dc.date.accessioned2020-06-21T15:51:00Z
dc.date.available2020-06-21T15:51:00Z
dc.date.issued1999
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Işıldak] İbrahim, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Asan] Adem, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA simple spectrophotometric flow-injection method is reported for the highly sensitive and fast determination of copper(II). The method is based on the formation of coloured Cu(II)-(4-methylpiperidinedithiocarbamate)<inf>2</inf> complex when the copper solutions are introduced into a tertiary reagent stream containing 4-methylpiperidinedithiocarbamate. The coloured complex is then selectively monitored at 435 nm. To increase interactions between copper(II) and colour forming reagent and preconcentrate of copper(II), a microcolumn containing strong cation exchange resins was placed between injection manifold and spectrophotometer. The system required no mixing chamber and allowed a sample throughput > 60 sample h-1. The calibration graph was linear in the range 5-100 μg 1-1. The detection limit was < 0.5 μg 1-1 for 20 μl injection volume of copper(II) ion solution. The developed method was applied to environmental, copper processing water, and ore samples.en_US
dc.identifier.doi10.1016/S0039-9140(98)00241-0
dc.identifier.endpage224en_US
dc.identifier.issn0039-9140
dc.identifier.issn1873-3573
dc.identifier.issue1en_US
dc.identifier.pmid18967461
dc.identifier.scopus2-s2.0-0345320395
dc.identifier.scopusqualityQ1
dc.identifier.startpage219en_US
dc.identifier.urihttps://doi.org/10.1016/S0039-9140(98)00241-0
dc.identifier.volume48en_US
dc.identifier.wosWOS:000077958700025
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofTalantaen_US
dc.relation.journalTalantaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject4-Methylpiperidine-Dithiocarbamateen_US
dc.subjectCopper(II) Determinationen_US
dc.subjectFlow-Injection Photometric Methoden_US
dc.subjectMicrocolumnen_US
dc.titleSpectrophotometric Determination of Copper(II) at Low μg 1-1 Levels Using Cation-Exchange Microcolumn in Flow-Injectionen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files