Publication:
Radioisotopic Evaluation of Malignant Lung Tumors: A Technetium-99m Methoxy-Isobutylisonitrile Study

dc.authorscopusid7101877713
dc.authorscopusid57210717291
dc.authorscopusid6701771541
dc.authorscopusid16634677600
dc.authorscopusid6603141222
dc.authorscopusid35582867600
dc.authorscopusid35582867600
dc.contributor.authorŞahin, M.
dc.contributor.authorOzcan, A.
dc.contributor.authorBernay, I.
dc.contributor.authorBaşoǧlu, T.
dc.contributor.authorDemirçali, A.E.
dc.contributor.authorUzun, O.
dc.contributor.authorErkan, L.
dc.date.accessioned2025-12-11T02:00:39Z
dc.date.issued1999
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Şahin] Murathan, Department of Nuclear, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Ozcan] A., Department of Nuclear, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Bernay] Irem, Department of Nuclear, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Başoǧlu] Tarik, Department of Nuclear, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Demirçali] Arif Engin, Department of Nuclear, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Uzun] Oǧuz, Department of Nuclear, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Erkan] Levent, Department of Nuclear, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractTumor imaging with myocardial perfusion agents has been a focal point for researchers. A kinetic study with (99m)Technetium- methoxyisobutylisonitrile ((99m)Tc-MIBI) was performed to evaluate the tumor uptake of this radiopharmaceutical in lung cancer. Thirty-five patients with lung cancer were studied. In 21 (60%) patients, there were regions of high uptake of (99m)Tc-MIBI in the lesions. Heart/tumor, (H/T), heart/lung (H/L) and tumor/lung (T/L) ratios were obtained. H/T and H/L ratios were 1.66±0.22 and 2.10±0.28 in 2-3 min, and 1.69±0.25 and 2.14±0.27 in 29-30 min respectively. The T/L ratio was 1.28±0.10 in 2-3 min and 1.29±0.14 in 29- 30 min. While the differences between H/T and H/L ratios were statistically significant, there were no significant differences between early and late uptake ratios. Seventy per cent (7/10) of small cell and 56% (14/25) of squamous cell cancers were detected visually. (99m)Tc-MIBI uptake in small cell tumors was higher than in squamous cell tumors. Tumor blood flow was seen in the systemic phase of the radiopharmaceutical as the blood supply of the tumor was the bronchial artery. The sensitivity of (99m)Tc-MIBI planar scintigraphy for lung cancer detection was inadequate, and the early and delayed ratios revealed that small cell cancer showed higher (99m)Tc-MIBI accumulation than squamous cell cancer.en_US
dc.identifier.endpage140en_US
dc.identifier.issn1300-0144
dc.identifier.issn1303-6165
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-0033037353
dc.identifier.scopusqualityQ1
dc.identifier.startpage135en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12712/47551
dc.identifier.volume29en_US
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.relation.ispartofTurkish Journal of Medical Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectLung Canceren_US
dc.subjectPlanar Scintigraphyen_US
dc.subjectTechnetium -99 M Methoxyisobutylisonitrileen_US
dc.titleRadioisotopic Evaluation of Malignant Lung Tumors: A Technetium-99m Methoxy-Isobutylisonitrile Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files