Publication:
Ultrasound Assessment of Diaphragm Thickness in Athletes

dc.authorwosidPolat, Ahmet/O-6352-2014
dc.authorwosidBostancı, Özgür/P-9710-2017
dc.authorwosidErai̇l, Serhat/Grf-6363-2022
dc.contributor.authorErail, Serhat
dc.contributor.authorBostanci, Ozgur
dc.contributor.authorPolat, Ahmet Veysel
dc.date.accessioned2025-12-11T00:46:41Z
dc.date.issued2022
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Erail, Serhat; Bostanci, Ozgur] Ondokuz Mayis Univ, Fac Yasar Dogu Sport Sci, TR-55100 Samsun, Turkey; [Polat, Ahmet Veysel] Ondokuz Mayis Univ, Dept Radiol, Samsun, Turkeyen_US
dc.description.abstractThe main purpose of this study was to examine the correlation between the aerobic and anaerobic performance of diaphragm thickness in athletes. That study was conducted with 15 team athletes (TA) (age 21.80 +/- 2.40 years), 15 individual athletes (IA) (age 18.93 +/- 2.31 years) and the control group (CON) 10 people living sedentary lifestyles (age 23.60 +/- 2.91 years). In this study, diaphragm muscle thickness (B-mode ultrasonography), respiratory function (spirometry and maximum inspiratory (MIP) and expiratory pressures (MEP), aerobic capacity yo-yo intermittent endurance Test 1 (YYIET-1), and anaerobic power by Monark 834 E were assessed. The diaphragm thickness was determined from the intercostalspace between the 8th and 9th ribs at the expiration time by ultrasound and from the intercostal space between the 10th and 11th ribs at inspiration and then, the thickness of the diaphragm was measured from the diaphragm is seen best. There was a positive correlation between DiT(ins)(r = 0.477) and DiT(ins-ex)(r = 0.473) parameters of TA. In IA, there was a significant correlation between DiT(ins) and DiT(ins)-ex parameters and Peak Power (r = 0.495 and 0.435, respectively) and average power (r = 0.483 and 0.446, respectively). No significant correlation in all parameters of the CON group (p<0.05). As a result, it was determined that athletes with high diaphragm thickness had higher anaerobic performance, and athletes with thinner diaphragm thickness had better VO(2)Max capacity. The diaphragm thickness of the athletes in individual branches was thicker than the team athletes, and their anaerobic performance was also higher.en_US
dc.description.sponsorshipOndokuz Mayis Universty Scientific Research Projects Commission [PYO.YDS.1904.18.005]en_US
dc.description.sponsorshipThis study was supported by Ondokuz Mayis Universty Scientific Research Projects Commission with project number PYO.YDS.1904.18.005.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.endpage383en_US
dc.identifier.issn0717-9502
dc.identifier.issn0717-9367
dc.identifier.issue2en_US
dc.identifier.scopusqualityQ3
dc.identifier.startpage376en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12712/39140
dc.identifier.volume40en_US
dc.identifier.wosWOS:000800856600015
dc.identifier.wosqualityQ4
dc.language.isoenen_US
dc.publisherSociedad Chilena de Anatomíaen_US
dc.relation.ispartofInternational Journal of Morphologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectRespiratoryen_US
dc.subjectPulmonaryen_US
dc.subjectPerformanceen_US
dc.subjectDiaphragmen_US
dc.subjectMuscle Thicknessen_US
dc.titleUltrasound Assessment of Diaphragm Thickness in Athletesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files