Publication:
Solid-Contact Polyvinyl Chloride Membrane Electrode Based on the Bis[(2-(hydroxyethylimino)phenolato]copper(II) Complex for Trace Level Determination of Copper Ions in Wastewater

dc.authorscopusid6701763136
dc.authorscopusid25921912000
dc.authorscopusid56110164500
dc.authorscopusid56110004000
dc.authorscopusid28067744200
dc.authorscopusid56511466800
dc.contributor.authorAndaç, M.
dc.contributor.authorF.
dc.contributor.authorBilir, S.
dc.contributor.authorA.
dc.contributor.authorDemir, S.
dc.contributor.authorUzun, H.
dc.date.accessioned2020-06-21T13:57:30Z
dc.date.available2020-06-21T13:57:30Z
dc.date.issued2014
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [null] null, Department of Chemistry, Erzincan Binali Yıldırım Üniversitesi, Erzincan, Turkey; [Bilir] Seda, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [null] null, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Demir] Serkan, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Uzun] Harun, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA miniaturized solid-contact polyvinyl chloride membrane electrode based on the bis[(2-(hydroxyethylimino)phenolato]copper(II) complex has been prepared for the determination of Cu(II) ion in real samples. The influence of coating membrane composition, pH, and possible interfering cations on the response of the ion-selective electrode was investigated. A number of membranes at different compositions were prepared and their Cu2+ sensing capabilities were investigated. The best results for Cu2+ sensing was obtained for the electrode membrane containing ionophore - 2-nitrophenyloctyl ether-polyvinyl chloride and potassium tetrakis(p-chlorophenyl)borate in a ratio of 4:65:30:1 (w/w, mg), respectively. The prepared electrode exhibited a near-Nernstian response (28.3 mV/decade) to Cu2+ in the concentration range from 1.0 × 10-6 to 1.0 × 10-1 mol/L with a limit of detection of 8.3 × 10-7 mol/L. The potentiometric response of the electrode was independent from the pH of the test solution in the pH range of 3.0-6.0. The electrode has a very short response time, about 15 s, and it can be used over a period of 3 months without any divergence in potential. The electrode has been successfully applied as an indicator electrode in potentiometric titration of Cu(II) ions with ethylenediaminetetraacetic acid and in the determination of Cu(II) in wastewater of the copper processing industry. © 2014 Published by NRC Research Press.en_US
dc.identifier.doi10.1139/cjc-2013-0530
dc.identifier.endpage328en_US
dc.identifier.issn0008-4042
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-84898077817
dc.identifier.scopusqualityQ4
dc.identifier.startpage324en_US
dc.identifier.urihttps://doi.org/10.1139/cjc-2013-0530
dc.identifier.volume92en_US
dc.identifier.wosWOS:000334031500009
dc.identifier.wosqualityQ4
dc.language.isoenen_US
dc.publisherCanadian Science Publishingen_US
dc.relation.ispartofCanadian Journal of Chemistryen_US
dc.relation.journalCanadian Journal of Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCopper Selective Electrodesen_US
dc.subjectPotentiometryen_US
dc.subjectWastewater Analysisen_US
dc.titleSolid-Contact Polyvinyl Chloride Membrane Electrode Based on the Bis[(2-(hydroxyethylimino)phenolato]copper(II) Complex for Trace Level Determination of Copper Ions in Wastewateren_US
dc.typeArticleen_US
dspace.entity.typePublication

Files