Publication:
An ınvestigation into the in-vitro effectiveness of electrolyzed water against various microorganisms

dc.contributor.authorYanik K.
dc.contributor.authorKaradag A.
dc.contributor.authorUnal N.
dc.contributor.authorOdabasi H.
dc.contributor.authorEsen S.
dc.contributor.authorGunaydin M.
dc.date.accessioned2020-06-21T09:42:55Z
dc.date.available2020-06-21T09:42:55Z
dc.date.issued2015
dc.departmentOMÜen_US
dc.department-tempYanik, K., Department of Medical Microbiology, Ondokuz Mayis University, Samsun, Turkey -- Karadag, A., Department of Medical Microbiology, Ondokuz Mayis University, Samsun, Turkey -- Unal, N., Adana Numune Education and Research Hospital Laboratory of Microbiology, Adana, Turkey -- Odabasi, H., Department of Medical Microbiology, Ondokuz Mayis University, Samsun, Turkey -- Esen, S., Infectious Diseases and Medical Microbiology, Ondokuz Mayis University, Samsun, Turkey -- Gunaydin, M., Department of Medical Microbiology, Istanbul University, Istanbul, Turkey --en_US
dc.description.abstractThe aim of this study was to investigate the in-vitro antimicrobial activity of usage and normal concentrations of electrolyzed water in hospital. In our study, the effects of different concentrations of electrolyzed water named Envirolyte® (Industries International Ltd., Estonia) on two gram positive, four gram negative standard strains and clinical isolates of four gram negative, two gram positive, one spore-forming bacillus and Myroides spp strains that lead to hospital infections were researched. The effects of different concentrations and different contact times of Envirolyte® electrolyzed water on cited strains were researched through method of qualitative suspension tests. Petri dishes fo bacteria have been incubated at 37°C 48 hours. Bactericidal disinfectant was interpreted to be effective at the end of the period due to the lack of growth. Solutions to which disinfectant were not added were prepared with an eye to control reproduction and controlcultures were made by using neutralizing agents. 1/1, 1/2, and 1/10 concentrations of Envirolyte® electrolyzed water were found to be effective on the bacteria that lead to hospital infections used during all test times. As a conclusion, based upon the results we acquired, it was observed that Envirolyte® electrolyzed water of 100% concentration would be convenient to be used for disinfection when diluted to a usage concentration of 1/10. © 2015, E-Century Publishing Corporation. All rights reserved.en_US
dc.identifier.endpage11469en_US
dc.identifier.issn1940-5901
dc.identifier.issue7en_US
dc.identifier.startpage11463en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12712/5215
dc.identifier.volume8en_US
dc.language.isoenen_US
dc.publisherE-Century Publishing Corporationen_US
dc.relation.journalInternational Journal of Clinical and Experimental Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBacteriaen_US
dc.subjectDisinfectanten_US
dc.subjectElectrolyzed wateren_US
dc.titleAn ınvestigation into the in-vitro effectiveness of electrolyzed water against various microorganismsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files