| dc.description.abstract | Amaç: Çalışmamızda, vertebra metastazlarında planlama tekniklerinin medulla spinalisin maksimum doz değerine (D-maks), homojenite (HI) ve konformalite indeksine (CI) etkisi araştırıldı. Materyal ve Metot: Bu çalışmada Ondokuz Mayıs Üniversitesi Radyasyon Onkolojisi Anabilim Dalı'nda vertebra metastazı nedeni ile tedavi edilen 20 hastanın 3 mm kesitlerle çekilen bilgisayarlı tomografi görüntüleri kullanıldı. Metastatik vertebranın bir üst ve altındaki vertebrayı içerecek şekilde klinik hedef hacim (CTV) oluşturuldu. CTV'ye her yönden 5 mm marjin verilerek planlanan hedef hacim (PTV) belirlendi. Her bir hasta için 3-boyutlu konformal radyoterapi (3D-CRT), alan-içinde-alan yoğunluk ayarlı radyoterapi (for-IMRT), IMRT ve hacimsel yoğunluk ayarlı ark tedavisi (VMAT) planlamaları yapıldı. PTV'ye doz, fraksiyon başına 3 Gray (Gy)'den toplam 30 Gy olarak tanımlandı. Elde edilen tüm verilerin istatistiksel analizinde SPSS 24.0 programı kullanıldı. Bulgular: Ortanca D-maks değerleri VMAT ve IMRT'de 3D-CRT ile for-IMRT'den istatistiksel olarak anlamlı düzeyde (p=0.000) daha düşüktü. Ortanca HI değerlerinin, VMAT ve IMRT tekniklerinde karşılaştırılmasında istatistiksel anlamlı fark saptanmazken (p>0.05), her iki tekniğin hem for-IMRT hem de 3D-CRT'den istatistiksel olarak anlamlı düzeyde (p=0.000) daha düşük HI değerlerine sahip olduğu belirlendi. Ortalama CI değerlerine göre tüm planlama teknikleri arasında istatistiksel anlamlı fark (p≤0.001) saptandı. En konformal planlama, VMAT tekniği ile elde edildi. Sonuç: IMRT veya VMAT tekniği ile vertebra metastazlarının tedavisinde daha iyi CI ve HI değerleri ile en düşük doz maksimum değeri elde edilerek tedavi planlaması yapılmaktadır. Anahtar Kelimeler: Vertebra; Medulla spinalis; 3D-CRT; IMRT; VMAT | |
| dc.description.abstract | Aim: In our study, the effect of planning techniques on vertebral metastases on maximal dose of medulla spinalis (D-max), homogeneity (HI) and conformity index (CI) was investigated. Material and Method: In this study, 20 patients treated with the reason of vertebrae metastases in Ondokuz Mayıs University Radiation Oncology Department, computerized tomography images taken with 3 mm cross section were used. The clinical target volume (CTV) was defined as the metastatic vertebrae with an upper and a lower vertebrae. The planned target volume (PTV) was created by giving a margin of 5 mm on each side of the CTV. Three-dimensional conformal radiotherapy (3D-CRT), field-in-field intensity modulated radiotherapy (for-IMRT), IMRT and volumetric modulated arc therapy (VMAT) planning were performed for each patient. The PTV dose was defined as a total of 30 Gy per 3 Gray (Gy) per fraction. Statistical analysis of all data was performed with the SPSS 24.0 program. Results: Median D-max values were statistically significantly lower (p = 0.000) than 3D-CRT and for-IMRT in VMAT and IMRT. There was no statistically significant difference between the median HI values in VMAT and IMRT techniques (p> 0.05) and both techniques had lower HI values statistically significant (p = 0.000) than both for-IMRT and 3D-CRT. A statistically significant difference (p≤0.001) was found between all planning techniques according to the mean CI values. The most conformal planning was achieved with the VMAT technique. Conclusion: In planning for vertebra metastases, planning with IMRT or VMAT technique is recommended to provide better CI and HI values and the lowest dose maximum. Keywords: Vertebra; Medulla spinalis; 3D-CRT; IMRT; VMAT | en_US |
| dc.format | X, 54 y. : tablo. , şekil. ; 30 sm. | en_US |
| dc.identifier.endpage | 67 | |
| dc.identifier.uri | https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=hcgrYffRbz0Z44UJEuLtweEosORoLej5CZeUU17ILusMpkJ8ikao4zpYb_bdvND8 | |
| dc.identifier.uri | http://libra.omu.edu.tr/tezler/122470.pdf | |
| dc.identifier.yoktezid | 519495 | |
| dc.language.iso | tr | en_US |
| dc.language.iso | tr | |
| dc.publisher | Ondokuz Mayıs Üniversitesi, Sağlık Bilimleri Enstitüsü | en_US |
| dc.relation.publicationcategory | Tez | en_US] |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Nükleer Mühendislik | |
| dc.subject | Onkoloji | |
| dc.subject | Neoplazm Metastazları | |
| dc.subject | Neoplazmlar | |
| dc.subject | Radyoterapi | |
| dc.subject | Radyoterapi-Bilgisayar Yardımlı | |
| dc.subject | Radyoterapi-Yoğunluk Ayarlı | |
| dc.subject | Nuclear Engineering | en_US |
| dc.subject | Spinal Kord Neoplazmları | |
| dc.subject | Oncology | en_US |
| dc.subject | Spinal Neoplazmlar | |
| dc.subject | Neoplasm Metastasis | en_US |
| dc.subject | Neoplasms | en_US |
| dc.subject | Radiotherapy | en_US |
| dc.subject | Radiotherapy-Computer Assisted | en_US |
| dc.subject | Radiotherapy-Intensity-Modulated | en_US |
| dc.subject | Spinal Cord Neoplasms | en_US |
| dc.subject | Spinal Neoplasms | en_US |
| dc.subject.other | TEZ YÜK LİS D674v 2018 | en_US |
| dc.title | Vertebra Metastazlarında Farklı Planlama Teknikleri İle Medulla Spinalisin Maksimum Doz Değerinin Karşılaştırılması | |
| dc.title | Comparison of Maximum Dose Value of Medulla Spinal With Different Planning Techniques in Vertebra Metastases | en_US |
| dc.type | Master Thesis | en_US |
| dspace.entity.type | Publication |