Publication:
The Effect of the Temperature Changes of EDTA and MTAD on the Removal of the Smear Layer: A Scanning Electron Microscopy Study

dc.authorscopusid56221938900
dc.authorscopusid57223210195
dc.contributor.authorÇiçek, E.
dc.contributor.authorKeskin, Ö.
dc.date.accessioned2020-06-21T13:46:47Z
dc.date.available2020-06-21T13:46:47Z
dc.date.issued2015
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Çiçek] Ersan, Department of Endodontics, Zonguldak Bulent Ecevit University, Zonguldak, Zonguldak, Turkey; [Keskin] Özgür, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractThe purpose of this study was to determine the effectiveness of EDTA and MTAD at different temperatures as a final irrigant to remove the smear layer after the use of 5.25% NaOCl. Seventy-eight human mandibular premolars with single straight canal were prepared by a crown-down technique using rotary 0.06 taper nickel-titanium files. Final irrigation was performed with EDTA and MTAD at different temperatures. The removal of the smear layer in the coronal, middle and apical level of each canal was examined under scanning electron microscope. No difference was found between the EDTA and MTAD at 4°C, 25°C, and 37°C temperatures regardless of the canal level (coronal, middle and apical) (P = 0.286). In EDTA-25, EDTA-37, MTAD-25, and MTAD-37 groups, the difference among the coronal, middle, and apical levels were statistically no significant (P > 0.05). Our findings showed that EDTA and MTAD at 25°C and 37°C are more effective than EDTA and MTAD at 4°C even in the apical level. © 2015 Wiley Periodicals, Inc.en_US
dc.identifier.doi10.1002/sca.21198
dc.identifier.endpage196en_US
dc.identifier.issn0161-0457
dc.identifier.issn1932-8745
dc.identifier.issue3en_US
dc.identifier.pmid25739528
dc.identifier.scopus2-s2.0-84931576490
dc.identifier.scopusqualityQ2
dc.identifier.startpage193en_US
dc.identifier.urihttps://doi.org/10.1002/sca.21198
dc.identifier.urihttps://hdl.handle.net/20.500.12712/14356
dc.identifier.volume37en_US
dc.identifier.wosWOS:000356365000005
dc.language.isoenen_US
dc.publisherJohn Wiley and Sons Inc. P.O.Box 18667 Newark NJ 07191-8667en_US
dc.relation.ispartofScanningen_US
dc.relation.journalScanningen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEDTAen_US
dc.subjectMTADen_US
dc.subjectScanning Electron Microscopyen_US
dc.subjectSmear Layeren_US
dc.subjectTemperatureen_US
dc.titleThe Effect of the Temperature Changes of EDTA and MTAD on the Removal of the Smear Layer: A Scanning Electron Microscopy Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication