Publication:
Exposure Assessment of Radio Frequency Electromagnetic Field Levels in Hospitals of Samsun Province, Turkey

dc.authorscopusid16230640200
dc.authorscopusid57205618850
dc.authorwosidKurnaz, Cetin/S-3469-2016
dc.contributor.authorKurnaz, Cetin
dc.contributor.authorAygun, Tulay
dc.contributor.authorIDKurnaz, Cetin/0000-0003-3436-899X
dc.date.accessioned2025-12-11T01:05:03Z
dc.date.issued2020
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Kurnaz, Cetin; Aygun, Tulay] Ondokuz Mayis Univ, Dept Elect & Elect Engn, Samsun, Turkeyen_US
dc.descriptionKurnaz, Cetin/0000-0003-3436-899Xen_US
dc.description.abstractWith the increase in the use of different types of electronic systems used inside and outside the hospital, the electromagnetic medium in the hospital has changed significantly. The increase in the number and type of EMF sources in sensitive mediums such as hospitals has led researchers to measure EMFs to assess the potential risk to patients and staff. For this reason, this study aims to determine the radio frequency electromagnetic field (RF-EMF) levels to which patients and staff are exposed voluntarily or unintentionally in the hospital environment and to control their compliance with the limits defined in the standards. In order to achieve these goals, three different types of RF-EMF measurements were carried out as, short-term, long-term, and band selective in 21 state hospitals in the Samsun Province, Turkey. Total RF-EMF in the band between 100 kHz and 3 GHz is measured using PMM-8053, while band selective is conducted using SRM-3006 in the frequency range from 27 MHz up to 3 GHz. The recorded RF-EMF values were statistically analyzed, and the main RF-EMF sources in the medium were determined. The highest average RF-EMF exposure level obtained for short-term measurements was 2.52 V/m. For long-term measurements, the highest average RF-EMF was 3.11 V/m and the highest mean RF-EMF was 2.29 V/m. Within our measurements, the limit of 3 V/m set by the Information and Communication Technologies Authority (ICTA) was exceeded in the hospital, although the highest RF-EMF was below the limit level set by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). Long-term measurement results showed that the RF-EMF level at midday was higher than at night; the highest RF-EMF was measured in the afternoon and during evening hours. The mean RF-EMF levels are 1.01 V/m, 1.15 V/m, 1.12 V/m, and 0.84 V/m, for morning, afternoon, evening, and night respectively. The RF-EMF level measured during the afternoon hours maybe about 37% higher than the RF-EMF levels measured at night. The main sources of total RF-EMF in the environment determined from the band-selective RF-EMF results were base stations located outside the hospital and their contribution to total RF-EMF was 92.6%. Systems that make the most contribution to the RF-EMF in the environment are base stations using the LTE 800, GSM 900, GSM 1800, LTE 1800, and UMTS 2100 frequency bands. Among these, the UMTS 2100 frequency band gave the highest contribution with 40.42%. With the use of these main RF-EMF sources, an empirical model that helps in computing the totalEof the medium with 99.8% accuracy was proposed.en_US
dc.description.sponsorshipOndokuz Mayis University [PYO. MUH.1904.17.017]en_US
dc.description.sponsorshipThis work was supported by Ondokuz Mayis University Research Fund, Graduate Thesis Support Program, and Project No: PYO. MUH.1904.17.017.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1007/s11356-020-09669-1
dc.identifier.endpage34017en_US
dc.identifier.issn0944-1344
dc.identifier.issn1614-7499
dc.identifier.issue27en_US
dc.identifier.pmid32557061
dc.identifier.scopus2-s2.0-85086733717
dc.identifier.scopusqualityQ1
dc.identifier.startpage34005en_US
dc.identifier.urihttps://doi.org/10.1007/s11356-020-09669-1
dc.identifier.urihttps://hdl.handle.net/20.500.12712/41213
dc.identifier.volume27en_US
dc.identifier.wosWOS:000541061700005
dc.language.isoenen_US
dc.publisherSpringer Heidelbergen_US
dc.relation.ispartofEnvironmental Science and Pollution Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectRadio Frequency Electromagnetic Field (RF-EMF)en_US
dc.subjectComprehensive RF-EMF Measurementen_US
dc.subjectHospitalen_US
dc.subjectBase Stationen_US
dc.subjectICNIRPen_US
dc.titleExposure Assessment of Radio Frequency Electromagnetic Field Levels in Hospitals of Samsun Province, Turkeyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files