Publication:
Clinical Bond Failure Rates of Adhesive Precoated Self-Ligating Brackets Using a Self-Etching Primer

dc.authorscopusid59748991100
dc.authorscopusid56231681800
dc.authorscopusid55995011100
dc.authorscopusid55349350500
dc.contributor.authorÖzer, M.
dc.contributor.authorBayram, M.
dc.contributor.authorDinçyürek, C.
dc.contributor.authorTokalak, F.
dc.date.accessioned2020-06-21T13:59:24Z
dc.date.available2020-06-21T13:59:24Z
dc.date.issued2014
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Özer] Mete, Department of Orthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Bayram] Mehmet, Department of Orthodontics, Karadeniz Technical University, Trabzon, Trabzon, Turkey; [Dinçyürek] Çagri,; [Tokalak] Fuat,en_US
dc.description.abstractObjective: To comparatively assess the failure rate of adhesive precoated (APC) self-ligating metal brackets bonded with two different enamel surface preparation techniques: self-etching primer (SEP) and conventional two-step etch and primer method (CM). Materials and Methods: Fifty-seven patients with complete permanent dentition were included in this study. A total of 1140 APC self-ligating brackets (3M Unitek, Monrovia, Calif) were bonded using a split-mouth design. For each patient, SEP (Transbond Plus SEP, 3M Unitek) and CM (37% phosphoric acid) were used in alternate quadrants. All brackets were bonded by the same investigator after pumicing and rinsing of all of the teeth. The number, site, and date of first-time bracket failures were monitored throughout orthodontic treatment (mean, 22 months). The survival rates of the brackets were estimated by Kaplan-Meier and log-rank tests (P < .05). The adhesive remnant index was used to determine the bond failure interface. Results: The bond failure rates were 2.97% and 2.18% for the CM and SEP, respectively. No statistically significant difference in failure rates was found between the groups. The bond failure sites were predominantly at the enamel-adhesive interface in both groups. Conclusion: This long-term in vivo study showed that the combined use of SEP and the APC bracket system can be used effectively for bonding brackets after pumicing the enamel surfaces in clinical orthodontics. © 2014 by The EH Angle Education and Research Foundation, Inc.en_US
dc.identifier.doi10.2319/022013-149.1
dc.identifier.endpage160en_US
dc.identifier.issn0003-3219
dc.identifier.issn1945-7103
dc.identifier.issue1en_US
dc.identifier.pmid23819593
dc.identifier.scopus2-s2.0-84891944390
dc.identifier.scopusqualityQ1
dc.identifier.startpage155en_US
dc.identifier.urihttps://doi.org/10.2319/022013-149.1
dc.identifier.volume84en_US
dc.identifier.wosWOS:000329384800021
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherE H Angle Education Research Foundation, Incen_US
dc.relation.ispartofAngle Orthodontisten_US
dc.relation.journalAngle Orthodontisten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdhesive Precoated Bracketsen_US
dc.subjectSelf-Etching Primeren_US
dc.titleClinical Bond Failure Rates of Adhesive Precoated Self-Ligating Brackets Using a Self-Etching Primeren_US
dc.typeArticleen_US
dspace.entity.typePublication

Files