Comparison of Cannulated Screw with Tension Band Wiring Versus Compressive Cannulated Locking Bolt and Nut Device (Compressure) in Patella Fractures - A Cadaveric Biomechanical Study

dc.authorscopusid57192906504
dc.authorscopusid35965806700
dc.authorscopusid55344728700
dc.authorscopusid56804550700
dc.authorscopusid16244732100
dc.authorscopusid6507344700
dc.authorscopusid6507344700
dc.contributor.authorDomby, B.
dc.contributor.authorHenderson, E.
dc.contributor.authorNayak, A.
dc.contributor.authorErdoǧan, M.
dc.contributor.authorGutiérrez, S.
dc.contributor.authorSantoni, B.G.
dc.contributor.authorSagi, H.C.
dc.date.accessioned2020-06-21T14:17:11Z
dc.date.available2020-06-21T14:17:11Z
dc.date.issued2012
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Domby] Brian C., Department of Orthopaedics and Sports Medicine, University of South Florida, Tampa, Tampa, FL, United States; [Henderson] Eric R., Department of Orthopaedics and Sports Medicine, University of South Florida, Tampa, Tampa, FL, United States; [Nayak] Aniruddh N., Department of Orthopaedics and Traumatology, Ondokuz Mayis Üniversitesi, Samsun, Turkey, Phillip Spiegel Orthopaedic Research Laboratory, Foundation for Orthopaedic Research and Education, Tampa, FL, United States; [Erdoǧan] Murat, Department of Orthopaedics and Traumatology, Ondokuz Mayis Üniversitesi, Samsun, Turkey, Phillip Spiegel Orthopaedic Research Laboratory, Foundation for Orthopaedic Research and Education, Tampa, FL, United States; [Gutiérrez] Sergio, Phillip Spiegel Orthopaedic Research Laboratory, Foundation for Orthopaedic Research and Education, Tampa, FL, United States; [Santoni] Brandon G., Phillip Spiegel Orthopaedic Research Laboratory, Foundation for Orthopaedic Research and Education, Tampa, FL, United States; [Sagi] Henry Claude, Department of Orthopaedics and Sports Medicine, University of South Florida, Tampa, Tampa, FL, United Statesen_US
dc.description.abstractOBJECTIVE: The purpose of this study was to determine if proximity of cannulated lag screws to the articular surface of the patella combined with the tension band technique affects resistance to fracture gap opening, and if an alternative locking nut and bolt device without a tension band behaves in a biomechanically similar fashion. METHODS: Thirty-three cadaveric knees were allocated to 3 transverse patella fracture fixation groups: cannulated lag screw placement close to the articular (TBA) or non-articular (TBNA) surface with tension, and placement of a compressive locking nut and bolt device without tension band (CompresSURE) close to the articular surface. Knees were cycled through flexion-extension motion for 1000 cycles during which the fracture gap opening was quantified after the first flexion-extension cycle and after the 1000th cycle using an optoelectronic motion analysis system. RESULTS: After the first range of motion cycle, there was no significant difference in fracture gap opening between the 3 groups on the articular surface (P > 0.600). Total fracture gap displacement after the 1000th cycle was not significantly different between groups (P > 0.408). In general and irrespective of fixation technique, fractures opened in a wedge-like fashion with larger measured gap on the ventral surface relative to the articulating surface. CONCLUSIONS: When combined with the tension band, the proximity of cannulated lag screws to the articular surface did not affect resistance to fracture gap opening. Additionally, the stand-alone CompreSURE cannulated locking nut and bolt device without tension band was able to resist fracture gap opening in transverse fractures as effectively as the cannulated screw with tension band technique. Copyright © 2012 by Lippincott Williams & Wilkins.en_US
dc.identifier.doi10.1097/BOT.0b013e31826f5985
dc.identifier.endpage683en_US
dc.identifier.issn0890-5339
dc.identifier.issn1531-2291
dc.identifier.issue12en_US
dc.identifier.pmid22932750
dc.identifier.scopus2-s2.0-84870235983
dc.identifier.scopusqualityQ2
dc.identifier.startpage678en_US
dc.identifier.urihttps://doi.org/10.1097/BOT.0b013e31826f5985
dc.identifier.volume26en_US
dc.identifier.wosWOS:000311719100003
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.ispartofJournal of Orthopaedic Traumaen_US
dc.relation.journalJournal of Orthopaedic Traumaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBiomechanicsen_US
dc.subjectFractureen_US
dc.subjectLocking Nut and Bolten_US
dc.subjectPatellaen_US
dc.subjectTension Banden_US
dc.titleComparison of Cannulated Screw with Tension Band Wiring Versus Compressive Cannulated Locking Bolt and Nut Device (Compressure) in Patella Fractures - A Cadaveric Biomechanical Studyen_US
dc.typeArticleen_US