Publication:
Flow-Injection Potentiometric Applications of Solid State Li+ Selective Electrode in Biological and Pharmaceutical Samples

dc.authorscopusid25921912000
dc.authorscopusid6701763136
dc.authorscopusid6603596907
dc.contributor.authorColdur, F.
dc.contributor.authorAndaç, M.
dc.contributor.authorIşıldak, I.
dc.date.accessioned2020-06-21T14:46:41Z
dc.date.available2020-06-21T14:46:41Z
dc.date.issued2010
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Coldur] Fatih, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Işıldak] İbrahim, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA solid state polyvinyl chloride (PVC) membrane Li +-selective electrode was prepared and used as a detector in a low-dead volume flow through cell for the determination of Li + in pharmaceutical formulations and human serum samples. The potentiometric performance characteristics of the electrode were calculated under the optimized flow conditions. The electrode had near-Nernstian behavior in the concentration range of 0.1-100 mM (R 2 = 0.9981) with a slope of 61.34 mV decade -1 and detection limit of 0.080 mM. The relative standard deviation of the electrode response for eight replicate measurements of 100, 10, and 1 mM Li + was 0.43%, 0.45%, and 0.99%, respectively. The designed flow-through cell detector system revealed sampling rates of approximately 70 injections per hour. Flow injection potentiometry (FIP) results obtained for the pharmaceutical formulations were in good harmony with the atomic emission spectrophotometry results. However, the electrode could not be used successfully for the direct analysis of real serum samples in FIP. © 2010 Springer-Verlag.en_US
dc.identifier.doi10.1007/s10008-010-1070-4
dc.identifier.endpage2249en_US
dc.identifier.issn1432-8488
dc.identifier.issn1433-0768
dc.identifier.issue12en_US
dc.identifier.scopus2-s2.0-78649884715
dc.identifier.scopusqualityQ2
dc.identifier.startpage2241en_US
dc.identifier.urihttps://doi.org/10.1007/s10008-010-1070-4
dc.identifier.volume14en_US
dc.identifier.wosWOS:000284161300016
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofJournal of Solid State Electrochemistryen_US
dc.relation.journalJournal of Solid State Electrochemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAll-Solid State Lithium-Selective Electrodeen_US
dc.subjectFlow Injection Potentiometryen_US
dc.subjectPharmaceutical Formulationsen_US
dc.subjectSerum Analysisen_US
dc.subjectSolid-Contact Ion-Selective Electrodeen_US
dc.titleFlow-Injection Potentiometric Applications of Solid State Li+ Selective Electrode in Biological and Pharmaceutical Samplesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files