Publication:
Performance Analysis of a Latent Heat Storage System with Phase Change Material for New Designed Solar Collectors in Greenhouse Heating

dc.authorscopusid56450769700
dc.authorscopusid35613419200
dc.contributor.authorBenli, H.
dc.contributor.authorDurmuş, A.
dc.date.accessioned2020-06-21T14:53:58Z
dc.date.available2020-06-21T14:53:58Z
dc.date.issued2009
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Benli] Hüseyin, Department of Technical and Vocational Education, Firat Üniversitesi, Elazig, Turkey; [Durmuş] Aydın, Department of Mechanical Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractThe continuous increase in the level of greenhouse gas emissions and the rise in fuel prices are the main driving forces behind the efforts for more effectively utilize various sources of renewable energy. In many parts of the world, direct solar radiation is considered to be one of the most prospective sources of energy. In this study, the thermal performance of a phase change thermal storage unit is analyzed and discussed. The storage unit is a component of ten pieced solar air collectors heating system being developed for space heating of a greenhouse and charging of PCM. CaCl<inf>2</inf>6H<inf>2</inf>O was used as PCM in thermal energy storage with a melting temperature of 29 °C. Hot air delivered by ten pieced solar air collector is passed through the PCM to charge the storage unit. The stored heat is utilized to heat ambient air before being admitted to a greenhouse. This study is based on experimental results of the PCM employed to analyze the transient thermal behavior of the storage unit during the charge and discharge periods. The proposed size of collectors integrated PCM provided about 18-23% of total daily thermal energy requirements of the greenhouse for 3-4 h, in comparison with the conventional heating device. © 2009 Elsevier Ltd. All rights reserved.en_US
dc.identifier.doi10.1016/j.solener.2009.07.005
dc.identifier.endpage2119en_US
dc.identifier.issue12en_US
dc.identifier.scopus2-s2.0-71549118554
dc.identifier.startpage2109en_US
dc.identifier.urihttps://doi.org/10.1016/j.solener.2009.07.005
dc.identifier.volume83en_US
dc.identifier.wosWOS:000272526100002
dc.language.isoenen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.ispartofSolar Energyen_US
dc.relation.journalSolar Energyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGreenhouseen_US
dc.subjectLatent Heat Storage (LHS)en_US
dc.subjectPhase Change Material (PCM)en_US
dc.subjectSolar Air Collector (SAC)en_US
dc.subjectThermal Energy Storage (TES)en_US
dc.titlePerformance Analysis of a Latent Heat Storage System with Phase Change Material for New Designed Solar Collectors in Greenhouse Heatingen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files