Publication: Electrochemical Characterization of Luminol and Its Determination in Real Samples
| dc.authorscopusid | 6701743062 | |
| dc.authorscopusid | 56362486200 | |
| dc.authorscopusid | 56060054300 | |
| dc.contributor.author | Yildiz, G. | |
| dc.contributor.author | Tasdoven, U. | |
| dc.contributor.author | Menek, N. | |
| dc.date.accessioned | 2020-06-21T13:58:41Z | |
| dc.date.available | 2020-06-21T13:58:41Z | |
| dc.date.issued | 2014 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Yildiz] Gulcemal, Department of Chemistry, İstanbul Teknik Üniversitesi, Istanbul, Turkey; [Tasdoven] Ugur, Faculty of Science and Letters, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Menek] Necati, Faculty of Science and Letters, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | The electrochemical behavior of luminol, an important molecule in forensic science, was studied in Britton-Robinson buffer solution (pH 2-pH 13) at a glassy carbon electrode using cyclic voltammetry and differential pulse voltammetry techniques. Luminol showed a well-defined and irreversible oxidation peak at 0.33 V (vs. Ag/AgCl) in 0.05 mol L-1Britton-Robinson buffer solution at pH 12. The electrooxidation process of luminol was adsorption-controlled and irreversible over the pH range studied (2.0-13). The differential pulse voltammetric determination of luminol was carried out. Under optimal conditions, the glassy carbon electrode displayed a linear response over the range from 1.8 × 10-8to 4.5 × 10-4mol L-1luminol concentration, and statistical data were evaluated. A commercially available real sample that contained luminol was analyzed according to this method. The luminol percentage of the sample was obtained as 21.2 (±0.4)%. This journal is © the Partner Organisations 2014. | en_US |
| dc.identifier.doi | 10.1039/c4ay01281j | |
| dc.identifier.endpage | 7813 | en_US |
| dc.identifier.issn | 1759-9660 | |
| dc.identifier.issn | 1759-9679 | |
| dc.identifier.issue | 19 | en_US |
| dc.identifier.scopus | 2-s2.0-84907145195 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 7809 | en_US |
| dc.identifier.uri | https://doi.org/10.1039/c4ay01281j | |
| dc.identifier.volume | 6 | en_US |
| dc.identifier.wos | WOS:000342178500031 | |
| dc.identifier.wosquality | Q2 | |
| dc.language.iso | en | en_US |
| dc.publisher | Royal Society of Chemistry | en_US |
| dc.relation.ispartof | Analytical Methods | en_US |
| dc.relation.journal | Analytical Methods | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.title | Electrochemical Characterization of Luminol and Its Determination in Real Samples | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
