Publication:
Horasan Mortar Bearings in Base Isolation with Centuries Experiences

dc.authorscopusid55621227800
dc.authorscopusid55620217700
dc.authorscopusid57213413796
dc.contributor.authorKasimzade, A.A.
dc.contributor.authorTuhta, Sertac
dc.contributor.authorAtmaca, G.
dc.date.accessioned2020-06-21T09:43:32Z
dc.date.available2020-06-21T09:43:32Z
dc.date.issued2018
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Kasimzade] Azer Arastun, Department of Civil Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Tuhta] Sertaç, Department of Civil Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Atmaca] Gencay, Provincial Directorate of Disaster and Emergency, Samsun, Turkeyen_US
dc.description.abstractThe purpose of this study is to demonstrate the applicability of the Horasan mortar friction interface, which has been used for many long years in the past historical periods, as a seismic isolator in lightweight building structures with no overturning moment. To this end a four-storey hospital building has been selected as an example. Using the beyond-linear mathematical model simulation the results for Horasan mortar, stainless steel, gray-iron/mortar friction interfaces have been compared. For each interface the base acceleration is seen to be reduced in the ratio of 45, 38, 33% compared to the built-in building. For complete these favorable results-NSI device's material stress-and strain rang assessment have been modeled by the FEM in ANSYS, LS-DYNA environments and compute results to be compared to the related material ultimate values. Generally different devices are used to restore the superstructure to the initial position. In this study it has been proven that the earthquake has a restoring property and this phenomena have been used as the indirect restoring device. Full details of the application of Horasan mortar, which is economically favorable and has been used for many centuries in the history as a friction interface, has been given. © Springer International Publishing AG.en_US
dc.identifier.doi10.1007/978-3-319-93157-9_3
dc.identifier.endpage127en_US
dc.identifier.isbn9783319931562
dc.identifier.isbn9783319931579
dc.identifier.scopus2-s2.0-85077784656
dc.identifier.startpage85en_US
dc.identifier.urihttps://doi.org/10.1007/978-3-319-93157-9_3
dc.language.isoenen_US
dc.publisherSpringer International Publishingen_US
dc.relation.journalSeismic Isolation, Structural Health Monitoring, and Performance Based Seismic Design in Earthquake Engineering: Recent Developmentsen_US
dc.relation.publicationcategoryKitap Bölümü - Uluslararasıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDurable Natural Seismic Isolation (NSI) Deviceen_US
dc.subjectEarthquake Response Controlen_US
dc.subjectLS-DYNA Finite Element Modelingen_US
dc.subjectNonlinear ANSYSen_US
dc.subjectPure Frictionen_US
dc.titleHorasan Mortar Bearings in Base Isolation with Centuries Experiencesen_US
dc.typeBook Parten_US
dspace.entity.typePublication

Files