Publication:
Effect of Adaptive Motion on Cyclic Fatigue Resistance of R-Endo Nickel-Titanium File

dc.authorscopusid56348812200
dc.authorscopusid57193440556
dc.authorscopusid57191441826
dc.contributor.authorOzyurek, T.
dc.contributor.authorYılmaz, K.
dc.contributor.authorUslu, G.
dc.date.accessioned2020-06-21T09:04:45Z
dc.date.available2020-06-21T09:04:45Z
dc.date.issued2017
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Ozyurek] Taha, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Yılmaz] Koray, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Uslu] Gulşah, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractAim: The aim of this study is to evaluate R-Endo R3 file's resistance to cyclic fatigue in comparison with continuous rotation movement and 'Adaptive Motion' (AM) movement under dynamic model. Materials and Methods: Forty pieces of R-Endo R3 (25.04) files (lot no: 062011) were included in the study. Cyclic fatigue tests were performed with specifically manufactured dynamic cyclic testing device. The device has an artificially prepared canal with 60° curvature angle and 5 mm curvature radius. The canal inner diameter is 1.5 mm and the center of curvature is located 5 mm coronally from the apex. The files were randomly divided into two groups (n = 20) and the following procedures were performed - Group 1: Rotary motion (RM), Group 2: AM. Time to fracture was recorded and the number of cycles to failure for each instrument was obtained. Statistical analyses were performed using Student's t-test. The statistical significant level was set at P < 0.05. Results: AM group had a significantly higher cyclic fatigue resistance compared with RM group (P < 0.001). Conclusion: Within the limitation of the present study, it was found that 'Adaptive Motion' statistically increases the resistance to cyclic fatigue of R-Endo R3 files, manufactured for retreatment. © 2017 Saudi Endodontic Journal Published by Wolters Kluwer - Medknow.en_US
dc.identifier.doi10.4103/1658-5984.205123
dc.identifier.endpage86en_US
dc.identifier.issn2278-9618
dc.identifier.issn2320-1495
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-85018971062
dc.identifier.scopusqualityQ3
dc.identifier.startpage82en_US
dc.identifier.urihttps://doi.org/10.4103/1658-5984.205123
dc.identifier.volume7en_US
dc.language.isoenen_US
dc.publisherMedknow Publications B9, Kanara Business Centre, off Link Road, Ghatkopar (E) Mumbai 400 075en_US
dc.relation.ispartofSaudi Endodontic Journalen_US
dc.relation.journalSaudi Endodontic Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdaptive Motionen_US
dc.subjectDynamic Cyclic Fatigue Testen_US
dc.subjectEndodonticsen_US
dc.subjectNickel-Titaniumen_US
dc.subjectR-Endoen_US
dc.titleEffect of Adaptive Motion on Cyclic Fatigue Resistance of R-Endo Nickel-Titanium Fileen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files