Publication:
An Efficient Methodology Based on Coverage Area to Modify Location and Power Ratings of Distribution Transformers

dc.authorscopusid57215411486
dc.authorscopusid35103686000
dc.authorscopusid22433630600
dc.authorscopusid6603093123
dc.authorscopusid57223405805
dc.authorwosidTerzi, Ümit/Aay-6742-2020
dc.authorwosidAkar, Onur/Caa-2873-2022
dc.authorwosidAkar, Onur/Caa-2873-2022
dc.authorwosidSonmezocak, Temel/Hoc-4653-2023
dc.authorwosidPetrichenko, Lubov/Abb-6230-2020
dc.contributor.authorAkar, Onur
dc.contributor.authorTerzi, Umit Kemalettin
dc.contributor.authorOzgonenel, Okan
dc.contributor.authorPetrichenko, Lubov
dc.contributor.authorSonmezocak, Temel
dc.contributor.authorIDAkar, Onur/0000-0001-9695-886X
dc.date.accessioned2025-12-11T00:51:09Z
dc.date.issued2021
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Akar, Onur] Istanbul Gedik Univ, Dept Elect & Automat, TR-34876 Istanbul, Turkey; [Terzi, Umit Kemalettin] Marmara Univ, Dept Elect Elect Engn, TR-34722 Istanbul, Turkey; [Ozgonenel, Okan] Ondokuz Mayis Univ, Dept Elect Elect Engn, TR-55270 Samsun, Turkey; [Petrichenko, Lubov] Riga Tech Univ, Fac Power & Elect Engn, LV-1658 Riga, Latvia; [Sonmezocak, Temel] Istanbul Gedik Univ, Dept Elect & Energy, TR-34876 Istanbul, Turkeyen_US
dc.descriptionAkar, Onur/0000-0001-9695-886X;en_US
dc.description.abstractThe Technology development and rising standards of living are increasing the demand for electricity in city centres. In addition, the density of electric power in different areas of a city changes with the construction of new residential areas. Variation in load density can be managed by adjusting the voltage on distribution lines, installing new lines and transformer centres, and reconfiguring existing lines and transformer centres. In this study, the Istanbul Uskudar District of Kanlica-Cubuklu Region was examined and coverage areas were modified depending on the load density and power of the existing transformers. A novel systematic approach to determine the coverage area of transformers is presented. In this approach, the coverage area and overlap of each transformer with its neighbours were determined. Subsequently, transformers that are under-used or have significant overlap with neighbouring transformers were removed from the network. The transformers were placed into an optimal structure in the network by distributing the load of an excluded transformer to its nearest neighbours. This approach further allows the minimum route for the high voltage distribution wiring between transformers and cost to be determined.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1109/TPWRD.2020.3025858
dc.identifier.endpage2714en_US
dc.identifier.issn0885-8977
dc.identifier.issn1937-4208
dc.identifier.issue5en_US
dc.identifier.scopus2-s2.0-85116018440
dc.identifier.scopusqualityQ1
dc.identifier.startpage2705en_US
dc.identifier.urihttps://doi.org/10.1109/TPWRD.2020.3025858
dc.identifier.urihttps://hdl.handle.net/20.500.12712/39679
dc.identifier.volume36en_US
dc.identifier.wosWOS:000698898900017
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherIEEE-Inst Electrical Electronics Engineers Incen_US
dc.relation.ispartofIEEE Transactions on Power Deliveryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectSubstationsen_US
dc.subjectDistribution Networksen_US
dc.subjectPlanningen_US
dc.subjectUrban Areasen_US
dc.subjectOptimizationen_US
dc.subjectSociologyen_US
dc.subjectStatisticsen_US
dc.subjectCoverage Areaen_US
dc.subjectDistribution Network Planningen_US
dc.subjectDistribution Transformeren_US
dc.subjectLoad Densityen_US
dc.subjectOptimizationen_US
dc.subjectSubstation Determinationen_US
dc.titleAn Efficient Methodology Based on Coverage Area to Modify Location and Power Ratings of Distribution Transformersen_US