Publication:
Effect of Chitosan Nanoparticle, Qmix, and EDTA on Totalfill BC Sealers’ Dentinal Tubule Penetration: A Confocal Laser Scanning Microscopy Study

dc.authorscopusid57204392771
dc.authorscopusid56348812200
dc.authorscopusid57201642064
dc.authorscopusid55764843700
dc.contributor.authorUğur Aydın, Z.U.
dc.contributor.authorOzyurek, T.
dc.contributor.authorKeskin, B.
dc.contributor.authorBaran
dc.contributor.author, T.
dc.date.accessioned2020-06-21T13:05:28Z
dc.date.available2020-06-21T13:05:28Z
dc.date.issued2019
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Uğur Aydın] Zeliha, Department of Endodontics, Bolu Abant İzzet Baysal Üniversitesi, Bolu, Turkey; [Ozyurek] Taha, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Keskin] Neslihan Büşra, Balgat Oral and Dental Health Center, Ankara, Ankara, Turkey; Baran; [] Talat, Department of Chemistry, Aksaray Üniversitesi, Aksaray, Turkeyen_US
dc.description.abstractThe aim of the present study was to compare the effect of chitosan nanoparticle, QMix, and 17% EDTA on the penetrability of a calcium silicate-based sealer into dentinal tubules using a confocal laser scanning microscope (CLSM). Sixty mandibular premolar teeth were selected and randomly divided into three groups (n = 20) before root canal preparation according to the solution used in the final rinse protocol: chitosan, QMix, and EDTA groups. Twenty teeth of each group were filled with a TotalFill BC sealers’ single gutta-percha cone and with 0.1% rhodamine B. The specimens were horizontally sectioned at 3 and 5 mm from the apex, and the slices were analyzed in CLSM (4×). Total percentage and maximum depth of sealer penetration were measured using confocal laser scanning microscopy with using Image J analysis software. Dentinal tubule’s penetration depth, percentage, and area were measured using imaging software. Kruskal–Wallis test was used for statistical analysis. The level of significance was set at 5%. Results of Kruskal–Wallis analysis showed that there was a significant difference in the percentage and depth of sealer penetration among all groups at 3 and 5 mm level sections (P < 0.05). Within the groups, the minimum sealer penetration depth was recorded for chitosan nanoparticle group. Greater depth of sealer penetration was recorded at 5 mm as compared to 3 mm in all the groups. Within the limitation of the present study, it can be concluded that QMix and EDTA promoted sealer penetration superior to that achieved by chitosan nanoparticle. © 2018, The Society of The Nippon Dental University.en_US
dc.identifier.doi10.1007/s10266-018-0359-0
dc.identifier.endpage71en_US
dc.identifier.issn1618-1247
dc.identifier.issn1618-1255
dc.identifier.issue1en_US
dc.identifier.pmid29651668
dc.identifier.scopus2-s2.0-85045264387
dc.identifier.scopusqualityQ1
dc.identifier.startpage64en_US
dc.identifier.urihttps://doi.org/10.1007/s10266-018-0359-0
dc.identifier.volume107en_US
dc.identifier.wosWOS:000458044900009
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherSpringer Tokyo orders@springer.jpen_US
dc.relation.ispartofOdontologyen_US
dc.relation.journalOdontologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectChitosan Nanoparticleen_US
dc.subjectConfocal Microscopyen_US
dc.subjectEDTAen_US
dc.subjectQMixen_US
dc.subjectSealer Penetrationen_US
dc.titleEffect of Chitosan Nanoparticle, Qmix, and EDTA on Totalfill BC Sealers’ Dentinal Tubule Penetration: A Confocal Laser Scanning Microscopy Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files